10. Once the umbrellas are installed over the crosshead shaft, lift them up slightly and
insert the umbrella washers (49) through the upper opening of the umbrella.
Ensure the groove of the washer is facing up. Press top of umbrella down to seat
it over the umbrella washer and crosshead shaft.
Note: I04 pumps are not equipped with umbrellas.
11. Place o-rings (48) and piston
holders (47) in position on ends of
crosshead shaft.
12. Place ceramic cylinders (42) and
gaskets (43) in counterbore of
power frame (1).
13. Apply light oil or glycerin around the
OD of the piston cups (46), then
place them in the open end of the
cylinders. Use thumb to press the
cups down firmly into the piston
holder of each cylinder.
14. Insert the piston cup washers (45)
into the cylinders with the ribbed
side facing the piston cup.
15. Secure packing assembly using
cap screws (44). Torque to
specification per the Fastener
Torque Table in Section 10.0