![FMC Technologies MPU 1200 V6 Procedures Manual Download Page 10](http://html.mh-extra.com/html/fmc-technologies/mpu-1200-v6/mpu-1200-v6_procedures-manual_2312627010.webp)
MPU Dispatch Check Procedure
_____________________________________________________________________
____________________________________________________________________
Page 10 of 28 PRD-0000022543 Rev .00D
MNKS008 0.0 (4/08)
3.2. Results/Output
Registers
The following registers are the results registers of the MPU Series B.
They are all 32-bit float values. They are updated on the completion of
every measurement cycle.
Object
number
ModBus
Address
Description
Unit
0 0
Log
count
*1
-
1 2
Alarm
Status
*2
-
2 4
Flow
Velocity
m/s
3 6
Velocity
of
Sound
m/s
4 8
Actual
Volum
Flowrate
m
3
/h
5
10
Accumulated Volume Forward
m
3
6 12
Accumulated
Volume
Reverse
m
3
7
14
Accumulated error volume foward
m
3
8
16
Accumulated error volume reverse
m
3
9 18
Accumulated
time
*3
sec
10 20
Volume
Increment
*4
m
3
11
22
Increment Time Duration
*5
sec
12
24
Used Line Pressure
barA
13
26
Used Line Temperature
Celsius
14
28
Measured Flow Velocity path 1
m/s
15
30
Measured Flow Velocity path 2
m/s
16
32
Measured Flow Velocity path 3
m/s
17
34
Measured Flow Velocity path 4
m/s
18
36
Measured Flow Velocity path 5
m/s
19
38
Measured Flow Velocity path 6
m/s
20
40
Measured Velocity of Sound path 1
m/s
21
42
Measured Velocity of Sound path 2
m/s
22
44
Measured Velocity of Sound path 3
m/s
23
46
Measured Velocity of Sound path 4
m/s
24
48
Measured Velocity of Sound path 5
m/s
25
50
Measured Velocity of Sound path 6
m/s
26
52
Percentage Of Signals Used Transducer 1A
%
27
54
Percentage Of Bursts Used Transducer 2A
%
28
56
Percentage Of Bursts Used Transducer 3A
%
29
58
Percentage Of Bursts Used Transducer 4A
%
30
60
Percentage Of Bursts Used Transducer 5A
%
31
62
Percentage Of Bursts Used Transducer 6A
%
32
64
Percentage Of Bursts Used Transducer 6B
%
33
66
Percentage Of Bursts Used Transducer 5B
%
34
68
Percentage Of Bursts Used Transducer 4B
%
35
70
Percentage Of Bursts Used Transducer 3B
%
36
72
Percentage Of Bursts Used Transducer 2B
%