Types of drains:

 

 

1.

 

Wall drain: 

 

It must have a vertical ventilation duct with a diameter not less than 25 mm, which must be above the top cover of 

the oven, as shown in the picture.  

 

In case of not installing the vertical ventilation duct, a correct drainage is not warrantyd, being able to cause 

damages and the loss of the warranty.

 

 

 

 

 

Vertical ventilation duct 

Connection 40mm 

Clamp 

Connection 

Drain pipe 

MATERIAL NOT SUPPLIED 

15 

 
 

Summary of Contents for ST Compact Series

Page 1: ...Instruction manual Electric ovens Models STC 423 411 611 1011 E STC 411 611 1011 E W ATTENTION Please read these instructions before using the unit...

Page 2: ......

Page 3: ...rt 9 4 3 Preliminary operations 10 4 4 Placing the unit 10 5 INSTALLATION 12 5 1 Electrical connection 12 5 2 Water inlet 14 5 3 Draining connection 14 6 USE INSTRUCTIONS 18 6 1 Using the unit for the...

Page 4: ...014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 Manufacturer s addres FM CALEFACCI N S L CIF B 14343594 Manufacturer s address CTRA de Rute km 2 700 C P 14900 Lucena Cor...

Page 5: ...o process the repair of a unit under warranty or for any other query please contact your distributor and reference to the following description table Distributor Unit model Serial number Name Date of...

Page 6: ...ing parts use the ones supplied by FM only and follow the assembly instructions inside the packaging Non original spare parts do not ensure the correct operation of the unit and will imply the loss of...

Page 7: ...AD PER RACK 4 x Gn 2 3 12kg Max 10 kg per rack 4 x Gn 1 1 20 kg Max 15 kg per rack 6 x Gn 1 1 30 kg Max 15 kg per rack 10 x Gn 1 1 45 kg Max 15 kg per rack Never exceed the maximum load capacity to pr...

Page 8: ...mulated in the baking chamber and then become inflamed Only use the products recommended by the manufacturer Using other products may damage the unit and invalidate the warranty Only use home use clea...

Page 9: ...e transport incidences should be reported to FM Industrial to manage the replacement of the machine If visible damages are detected when receiving the packaged machine indicate hits to the oven at the...

Page 10: ...and some components may be destroyed If the oven is installed on an auxiliary support it must be fixed to it The facilities must be conditioned and meet the regulations in force with regard to safety...

Page 11: ...lacement without nearby heat sources Placement of equipment next to heat sources For maintenance operations we recommend a free working space of 500 mm approximately This unit is not suitable for buil...

Page 12: ...nicians and meet the regulations in force Preferably the electrical connection should be performed by mounting and electrical outlet of appropriate type and capacity for the maximum current absorbed b...

Page 13: ...power line protected by magneto thermal switch of suitable caliber as well as a fixed network connection for the connection of the devices Observe the color code of the wires An improper connection c...

Page 14: ...t exceeding 30 C If the pressure is higher than these values must install a pressure reducer at the entrance 5 3 Draining connection The connection of the oven drain must be made with discharge pipes...

Page 15: ...h must be above the top cover of the oven as shown in the picture In case of not installing the vertical ventilation duct a correct drainage is not warrantyd being able to cause damages and the loss o...

Page 16: ...2 Drain with separated funnel 3 Floor drain MATERIAL NOT SUPPLIED Connection 40mm Connection Clamp Drain pipe Distance 2 5mm Distance 2 5mm 16...

Page 17: ...ls do not warranty absolute thermal stability up to 250 C For the treaty of cooking vapours may adapt a capacitor allow vapours condense and expel to a drain Important Do not channel the vapour exhaus...

Page 18: ...ed to bake or regenerate fresh or frozen bakery and pastry products being the ranges of regulation SERIES STC E Temperature 0 C 250 C Time 0 min INF Humidity 0 100 The distance between trays is 80 mm...

Page 19: ...and If your appliance is working amber led located next to this command will turn on At the end of the cycle and powering the device the oven beeps You can also set infinite cooking time To do this tu...

Page 20: ...ill remain closed If you rotate it counterclockwise the shot will stay open Burn Hazard Before changing the chimney draft verify that the oven is cold If not you should use thermal mittens or similar...

Page 21: ...oth You can use FM detergent with a sprayer for a better cleaning of the oven s cooking chamber Warning Put on protective rubber gloves and mask or goggles before handling these chemicals Warning The...

Page 22: ...persists contact a specialised technician To find out where the safety thermostat is go to the Technical characteristics section and look for the model of your device If the failure persists contact a...

Page 23: ......

Page 24: ......

Reviews: