失控保护

Failsafe

设备通过解析失控标志位信息做出相应地应对即可);

2.  对于无失控标志位的信号 PWM/PPM/i-BUS,支持设置失控时信号 [ 无输出 ],通过 [ 无输出 ] 状态将“失控状态”信息传递给后续设备。

The failsafe function is used to output the channel value according to the out-of-control protection value set by the user after the receiver 

loses its signal and is out of control to protect the model and personnel.
This receiver supports two failsafe modes: 

ON

 and 

OFF

 

OFF

 It is no output  for the interface of i-BUS/PPM/PWM. 

ON

 Outputs the failsafe values set for the interface of i-BUS/PPM/PWM. 

Notes

:

 

1.  Because the S.BUS signal information contains failsafe flag bits, the failsafe information can be transmitted to the subsequent devices by 

the failsafe flag bits ruther than by OFF state. The subsequent devices gives response according to the analysed information for the failsafe 

flag bits.

2.  For the signal PWM/PPM/i-BUS without failsafe flag bits, it supports the setting of the output signal to 

OFF

 in case of failsafe, transmitting 

the failsafe information to the subsequent devices by OFF state. 

注意事项:

• 

使用前必须确保本产品与模型安装正确,否则可能导致模型发生严重损坏。

• 

关闭时,请务必先关闭接收机电源,然后关闭发射机。如果关闭发射机电源时接收机仍然在工作,将会导致遥控设备失控。失控保护设置不

合理可能引起事故。

• 

确保接收机安装在远离电机,电子调速器或电子噪声过多的区域。

• 

接收机天线需远离导电材料,例如金属棒和碳物质。为了避免影响正常工作,请确保接收机天线和导电材料之间至少有 1 厘米以上的距离。

• 

准备过程中,请勿连接接收机电源,避免造成不必要的损失。

Attentions:

• 

Make sure the product is installed and calibrated correctly, failure to do so may result in serious injury.

• 

Make sure the receiver's battery is disconnected before turning off the transmitter, failure to do so can result out of control.   Unreasonable 

setting of the Failsafe may cause accidents.

• 

Make sure the receiver is mounted away from motors, electronic speed controllers or any device that emits excessive electrical noise.

• 

Keep the receiver's antenna at least 1cm away from conductive materials such as carbon or metal.

• 

Do not power on the receiver during the setup process to prevent loss of control.