Flymaster HEART-G User Manual Download Page 6

 2  Getting started

Using the HEART-G is a very simple, since for the most part everything is automatic. On 

the back of the HEART-G there are 2 electrodes illustrated in blue on Figure 1

Figure 1

To start  using the HEART-G a one time pairing process is required to connect it to your 

Flymaster instrument. 

The HEART-G automatically switches on when it detects the human body contact on the 

electrodes, and automatically switches off after a short period after contact of the body to 

the electrodes is lost.

 2.1  Switching ON

Figure 2 Heart-G Position

Switching  the  HEART-G   “On”   and   “Off”   is   completely   automatic.  If   the   battery   in   the 

HEART-G  is in good condition the HEART-G is switched applying the chest start around 

the   chest   so   that   the   electrodes   make   contact   with   the   skin.   For   best   results,   we 

recommend:

Wear the chest strap against bare skin.

Be sure to moisten the electrodes before exercising. The humidity improves the 

conductivity and improves pulse detection.

Document version: 1.0

Page 6

Summary of Contents for HEART-G

Page 1: ...HEART G User manual Document version 1 0...

Page 2: ...y of this manual or of any revision hereto provided that such electronic or printed copy of this manual must contain the complete text of this copyright notice and provided further that any unauthoriz...

Page 3: ...ponsible for any damages resulting from incorrect or no data provided by the Flymaster HEART G Flight safety is the sole responsibility of the pilot It is unsafe to operate the Flymaster HEART G while...

Page 4: ...ontents 1 Introduction 5 2 Getting started 6 2 1 Switching ON 6 2 2 Switching OFF 7 3 Pairing the HEART G 8 4 Replacing the Battery 9 5 Calibrating the G Meter 10 6 Specifications 11 Document version...

Page 5: ...sum of the vectors of accelerations exerted on the pilot G Force is expressed in multiples of the acceleration of a standard gravity When no acceleration is exerted the system reports a value of1g ap...

Page 6: ...des and automatically switches off after a short period after contact of the body to the electrodes is lost 2 1 Switching ON Figure 2 Heart G Position Switching the HEART G On and Off is completely au...

Page 7: ...nse chest hair this will hamper contact of electrodes to the skin In dry cold climates skin dryness will affect the electrode contact so it may take several minutes for the chest belt to function stea...

Page 8: ...ure 3 RF Probes Screen The list includes all the RF probes previously paired as well as all the RF probes not paired but that are visible i e transmitting and in range If the HEART G is on and working...

Page 9: ...top your chest belt battery may need replacing To replace the chest belt battery Using a coin twist the battery cover counter clockwise until it clicks out of place Replace the old battery and close t...

Page 10: ...this case the accelerometer can be re calibrated by following this procedure Remove the battery from the HEART G Put the HEART G on a horizontal position place it on a horizontal surface with the batt...

Page 11: ...eps Min Range 0 1500 Heart Rate HR measuring range 40 240 bpm beats per minute Transmission Range 1 meter may decrease with low battery Water Resistant Splash proof Operating Environ ment temperature...