2.4 Fuel system
2.4.1 The standard fuel system consists of two polyethelene tanks linked
together with a balance pipe. As such they work as one single tank for
fuel management purposes.
2.4.2 Fuel is drawn from a single outlet through a single fuel tap which
isolates all supply.
2.4.3 Fuel is pumped by an engine driven mechanical fuel pump, and an
(optional) electrical back-up fuel pump. An anti vapour-lock restricted
return allows fuel flow back from the engine compartment to the fuel
tanks.
2.4.4 The tank outlet has a strainer, and an additional fuel filter is used in
the supply line.