We have set the receiver in toggle mode before delivery, if you want to use other modes, do as following operation.
1) Setting control mode Toggle: Only connect Jumper-2.
Control mode Toggle (with transmitter CB-1): Press -> On; Press again -> Off.
Press button of the transmitter: Output terminals outputs DC power, and the lamp is turned on.
Press button again: Output terminals stops outputting, and the lamp is turned off.
2) Setting control mode Momentary: Only connect Jumper-1.
Control mode Momentary (with transmitter CB-1): Press and hold -> On; Release -> Off.
Press and hold button of the transmitter: Output terminals outputs DC power, the lamp is turned on.
Release button of the transmitter: Output terminals stops outputting, the lamp is turned off.
3) Setting control mode Latched: Do not connect Jumper-1 and Jumper-2.
Control mode Latched (with transmitter CB-2): Press -> On, Press another button -> Off.
Press button A of the transmitter: Output terminals outputs DC power, and the lamp is turned on.
Press button B of the transmitter: Output terminals stops outputting, and the lamp is turned off.
Wired control terminals:
The receiver has wired control terminals, and you can connect external devices, sensors, or manual switches to the receiver's manual terminals, then
use them to trigger the receiver.
1) By low level signal:
You can connect external devices (with low level output signal) to trigger the receiver.
When external device outputs low level signal to terminals 1 () and terminal 2 (Signal -), the relay is activated, and Output terminals outputs
DC power, and the lamp is turned on.
When external device stops to output signal, the relay is deactivated, and Output terminals stops outputting, and the lamp is turned off.
2) By NO/NC contact:
You can connect manual switches (with NO/NC contact) to trigger the receiver.
When connect terminals 1 and 2 by manual switch, the relay is activated. Output terminals outputs DC power, and the lamp is turned on.
When disconnect terminals 1 and 2 by manual switch, the relay is deactivated. Output terminals stops outputting, and the lamp is turned off.
How to pair the transmitter to the receiver:
1) Press the learning button of receiver for 1- 2 seconds; signal LED on the receiver is on. The receiver enters into status of LEARNING.
2) Press any one button on transmitter. If signal LED flashes quickly 15 times and turns off, it means learning is successful.
3) When receiver is in the status of LEARNING, press again the learning button, signal LED turns off, learning process will be discontinued.
4) The receiver can learn several remote controls with different codes.
Delete all transmitters:
We have learned remote control to
the receiver. If you don’t want the receiver to work with the remote control, you can delete all codes of remote
controls, which are stored in the receiver.
Operation: Press and hold the learning button of receiver until signal LED flashes slowly; release the button, LED keeps slow flash. That means all
stored codes have been deleted successfully.