![FLYGT MAS 711 Installation And Operation Manual Download Page 103](http://html1.mh-extra.com/html/flygt/mas-711/mas-711_installation-and-operation-manual_2311483103.webp)
Settings with the Operator Panel,
Retrieve Sensor Information from Pump Memory
Retrieve Sensor Information from Pump Memory
Instruction
Follow these steps to retrieve sensor information from the pump memory:
Step
Action
Result
1
• Go to General con
fi
g (2.5) in
the Setup menu using up/down
arrow.
• Press OK and use down arrow
to enter menu Pump memory
(2.5.5).
• Press OK to enter edit mode.
The text is
fl
ashing.
2
• Select
Active
using the up/down
arrow.
• Press OK and con
fi
rm the change
with OK.
“Value saved” is displayed brie
fl
y.
3
• Go to menu Pump memory sync
(2.5.6) using the down arrow.
• Press OK to enter menu Copy all
from PM to MAS (2.5.6.1).
• Press OK to perform
Copy all
from PM to MAS
.
“Execute sync?” is displayed.
4
Press OK to con
fi
rm.
• “Wait” is displayed during the
synchronization
• After synchronization “Sync
executed” is displayed brie
fl
y and
then menu Copy all from PM to
MAS.
• The base unit is now set up
with the selection of sensors
in the actual pump and the
recommended factory alarm
settings.
103