4.13 No vibration
No vibration
Check whether the
motor is locked by
displacement
Reassemble
the motor
Check whether the
motor is broken
OK
Change the motor
D/L the latest edition,
Check whether it is OK
ok
Checking method
testing
the resistance of the motor
by multimeter, gearing to
the resistance, the
resistance of it is 22ohm in
general
Check whether there is
anyone broken of R1302
C1301 B1300 B1301
Change R1302
C1301 B1300 B1301
N
N
N
N
Y
Y
Y
Y
Change the CPU
Check whether the connection
of J9401 is OK
Reassemble the
Connector
N
Y