CIRCUIT CONNECTING DIAGRAM

14

2510-3A

3P-NT

V1.1

09-04

+

SW

+

J9

PH-3A

J4

PH-3A

U10

YSJZ

J7

2510-8A

U3

GD32F303VET6

S5

S4

S3

S2

S1

J10

PH-5A

J8

J6

XH-3A

J5

XH-3A

J3

2510-3A

J2

VH-2A

J1

VH-2A

FAN1

FAN2

BUS

DMX

DMX1

B

-

2

-

1

+

3

+

C

+

A

+

V1.04

1920-FG

PD

TEMP

D10

JR30

0R

JR31

0R

JR36

0R

JR34

0R

JR29

0R

JR28

0R

JR27

0R

JR26

0R

JR25

0R

JR24

0R

JR23

0R

JR22

0R

JR21

0R

JR20

0R

JR19

0R

JR18

0R

JR17

0R

R1

103

J7

J6

J5

J4

J3

J2

J1

D19

D18

D17

D16

D15

D14

D13

D12

D11

D9

D8

D7

D6

D5

D4

D3

D2

D1

L

E

D

 

b

o

a

rd

D

ri

v

e b

o

a

rd

D

is

p

la

y

 d

o

a

rd

M

a

g

n

e

ti

c c

o

d

in

g P

x

M

a

g

n

e

ti

c c

o

d

in

g P

 y

P

a

n

/T

il

t D

ri

v

e b

o

a

rd

BUS2

PY

BUS1

PX

+28V

X-SL

Y-MOTOR

V1.00

1920-XY

+28V

X-MOTOR

Y-SL

J5

J7

J3

J2

J4

J1

J9

J8

J6

U6

GD32F303CCT6

J11

J10

J1

J1

SW

Y

 m

o

to

r c

a

b

le

Y

X m

o

to

r c

a

b

le

: X

 

p

o

w

e

r s

u

p

p

ly

 

C

+

3

1

D

J11

PH-6A

J17

U20

GD32F303CCT6

J10

J14

J2

C49

J5

HB9500-2P

J1

J9

J12

J4

J7

J6

J13

J3

J16

J15

A

1920-QD

V1.05

B

PWM

FAN

TEMP

SIG

BUS2

BUS1

SW

2

ZOOM

ZOOM

Z

o

o

m m

o

to

r

Z

o

o

m m

o

to

r

H

a

ll p

la

te

F

a

n

 

p

o

w

e

r s

u

p

p

ly

 

P

o

s

it

iv

e p

o

w

e

r s

u

p

p

ly

N

e

g

a

ti

v

e p

o

w

e

r s

u

p

p

ly

X

L

R b

o

a

rd

Summary of Contents for Light Sky TX1920-HC

Page 1: ...Please read these user manual carefully before use Please read these user manual carefully before use TX1920 HC E mail n 43 Address No 43 Yunfeng Road Xiuquan Street Huadu District Guangzhou China...

Page 2: ...viced correctly and safely My company disclaims all liability for damage to the fitting or to other property or persons deriving from installation use and maintenance that have not been carried out in...

Page 3: ...ng a potential fire hazard Mounting surface and fire protection Keep all combustible materials at least 20 cm away from the fixture This lighting fixture is for professional use only it is not for hou...

Page 4: ...radiation Protection against explosion The protection screen lens or ultraviolet screen on the lamp can be damaged to the degree of failure if visible damage such as a crack or deep mark should be rep...

Page 5: ...ilitate quick operation and browse menus Display board can record device s using time show device s temperature channel data and software version Customizable Settings display menu Settings through th...

Page 6: ...in 7 Diameter m ft in 55 Diameter m ft in 5 16 5 1 3 4 3 1070 99 1000 93 1900 177 16700 1552 14600 1357 28700 2667 13 1 96 9 200 19 1600 149 1420 132 2750 256 394 37 350 33 670 62 6100 567 5400 501 9...

Page 7: ...power cord 6 ATTACHMENT AND BODY SIZE 422 338 211 321 216 296 153 303 400 244 232 216 179...

Page 8: ...support structure of the projector and then connected to the fixing point at the centre of the base 7 Make sure all parts for fixing the projector are in a good state of repair Make sure the point of...

Page 9: ...sure all the devices had been installed with natural operate press the power switch to check whether every thing is working normally L N Ground connection to the eiectricty mains must be carried out...

Page 10: ...9 DMX512 in signal end out in out in DMX output 1 Shield 2 Signal Signal Not connected Not connected 3 1 2 3 DMX input Shield Signal Signal Not connected Not connected 4 5 4 5...

Page 11: ...htness and wave length can not be produced exactly same by LED factory which would cause the color difference in the LED color fixture To solve the issue LIGHT SKY adopts a calibration system by calib...

Page 12: ...X live 1 Pan 0 255 2 Pan fine 0 255 3 Tilt 0 255 4 Tilt fine 0 255 5 P T Speed 0 255 6 Function 0 255 7 Dimmer 0 255 8 Dimmer fine 0 255 9 Strobe 0 255 10 Cold white 0 255 11 Warm white 0 255 12 CCT 0...

Page 13: ...Service Fixture state Memory IC OK Reset Error Pan Encodeer OK Reset Error Pan Drive IC OK Reset Error Tilt Encoder OK Reset Error Tilt Drive IC OK Reset Error Pan OK Reset Error Tilt OK Reset Error Z...

Page 14: ...10 PT swap on 111 120 PT swap off 121 130 Backlight time Always 131 140 Backlight time Auto 141 150 Linear 151 160 Square 161 170 I Square 171 180 Scurve 181 190 Led Hz 3000HZ 191 200 Led Hz 6000HZ 20...

Page 15: ...J4 J3 J2 J1 D19 D18 D17 D16 D15 D14 D13 D12 D11 D9 D8 D7 D6 D5 D4 D3 D2 D1 LED board Drive board Display doard Magnetic coding Px Magnetic coding P y Pan Tilt Drive board BUS2 PY BUS1 PX 28V X SL Y M...

Page 16: ...n begin to maintenance take down the light Please let the parts cool down 10 minute at least then begin to install 4 Please inspect the lens or other moving parts timing and keep them clear and static...

Page 17: ...is too long or interrupt 3 Please check the control system is not valid check the signal amplifier of chain connected is valid 4 Please check whether the communicate cable is too long or the other eq...

Page 18: ...17...

Reviews: