ATTACHMENT AND BODY SIZE

power

 

cord

1

Summary of Contents for Light Sky PL1215Z

Page 1: ...PL1215Z E mail n Address No 43 Yunfeng Road Xiuquan Street Huadu District Guangzhou China...

Page 2: ...iced correctly and safely My company disclaims all liability for damage to the fitting or to other property or persons deriving from installation use and maintenance that have not been carried out in...

Page 3: ...le materials at least 20 cm away from the fixture This lighting fixture is for professional use only it is not for household use Make sure all parts for fixing the projector are in a good state of rep...

Page 4: ...radiation Protection against explosion The protection screen lens or ultraviolet screen on the lamp can be damaged to the degree of failure if visible damage such as a crack or deep mark should be rep...

Page 5: ...ar circuit breaker with thermal protection Safety Devices Forced ventilation with axial fans Cooling Housing with high pressure engineering plastic anti UV anti high temperature and anti aging Outlook...

Page 6: ...2 12 5 16 5 1 4 4 7 5 16 5 R G B W RGB RBGW R G B W RGB RBGW 2250 209 5200 483 200 19 6250 581 6900 641 12650 1176 195 18 467 44 19 2 589 55 1035 96 841 78 510 47 1178 109 50 5 1500 139 1630 151 3060...

Page 7: ...Body Size Fig 2 2 2 4 2 334 289 380 312 276 312 289 432 6 ATTACHMENT AND BODY SIZE power cord 1...

Page 8: ...air Make sure the point of anchorage is stable before positioning the projector When suspending the fixture ensure that the supporting structure and all hardware used can hold at least 10 times the we...

Page 9: ...natural operate press the power switch to check whether every thing is working normally connection to the eiectricty mains must be carried out by a qualified electrical installer The N terminal is co...

Page 10: ...9 OUT DMX IN OUT IN SIGNAL END IN DMX output 1 Shield 2 Signal Signal Not connected Not connected 3 1 2 3 DMX input Shield Signal Signal Not connected Not connected 4 5 4 5 5...

Page 11: ...ge up Down arrowhead page down Left arrowhead reduce Right arrowhead increase Enter OK function Exit in the choice screen CONTROL PANEL 1 DOWN LEFT RIGHT ENTER UP 10 POWER IN POWER OUT DMX OUT DMX IN...

Page 12: ...r on time 0 99999H LED on time 0 99999H All time 0 99999H Temperatures 40 120 RDM info 0x3888XXXXXXXX Version VX XXX Person Led Hz 1200Hz 6000Hz 12000Hz 24000Hz Dimmer Curve Linear Square I Square Scu...

Page 13: ...Balance Red 125 255 Green 125 255 Blue 125 255 White 125 255 Factory Factory Reset Password YES NO Clear timers Power on time Password YES NO Led on time YES NO All time YES NO Developer Password LOG...

Page 14: ...obe effect from slow to fast 200 249 Random strobe effect from slow to fast 250 255 Reserved 4 0 255 0 100 Red 5 0 255 0 100 Green 6 0 255 0 100 Blue 7 0 255 0 100 White 8 Color Macro 0 3 Reserved 4 2...

Page 15: ...Circuit connecting diagram 14...

Page 16: ...down the light Please let the parts cool down 10 minute at least then begin to install 4 Please inspect the lens or other moving parts timing and keep them clear and static If find anything damaged or...

Page 17: ...long or interrupt 3 Please check the control system is not valid check the signal amplifier of chain connected is valid 4 Please check whether the communicate cable is too long or the other equipment...