background image

 

 

 

 

Operating manual 

 

 

 

 

 

 

 

 

 

 

with spare parts list 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Liquid Meter FMT 50 PP 

 
 

Contents

 

1.

 

Product description 

2

 

2.

 

Safety instructions 

2

 

3.

 

Technical Description 

4

 

4.

 

Operation 

4

 

5.

 

Fault monitoring 

5

 

6.

 

Meter programming 

5

 

7.

 

Spare parts construction and spare parts list 

8.   Dimensional Drawing 

9.  Chart of pressure loss 

10.  Features 

11.  Declaration of Conformity  

9

 

 

Summary of Contents for FMT 50 PP

Page 1: ...roduct description 2 2 Safety instructions 2 3 Technical Description 4 4 Operation 4 5 Fault monitoring 5 6 Meter programming 5 7 Spare parts construction and spare parts list 6 8 Dimensional Drawing...

Page 2: ...ir which in the case of volume flow transfers the meter pulses to a reed switch on the evaluation electronic system 2 Safety instructions The device is a state of the art piece of equipment and has be...

Page 3: ...erator If the personnel do not have the required knowledge they must be trained and instructed The operator must also ensure that the contents of the operating instructions are properly understood by...

Page 4: ...e LC display indicates the metered volume since the last reset The display has three digits before the decimal point and two after 0 01 litres is the minimum digital step The litre measurement unit op...

Page 5: ...ctor can be established a delivery must be made into a satisfactorily accurate vessel or undertaken by means of a reference meter The new calibrating factor is calculated as follows shown delivered ex...

Page 6: ...olding the Total and Reset keys at the same time when setting the measurement unit or calibrating factor is to delete all the meter values and carry out an initialisation Following values are initiali...

Page 7: ...uction and spare parts list Spare parts list Pos Description PP 10 Cover complete Battery A05 00 001 20 Measuring chamber typeplate A05 00 002 30 Battery 940 04 033 40 Four cylinder head screws DIN 91...

Page 8: ...range 0 8 40 mPa s Operating pressure 4 bar Burst pressure 9 bar Accuracy uncalibrated 2 Accuracy calibrated 1 Repeat accuracy 0 5 Nominal width 1 External thread Protection category IP 65 Battery Li...

Page 9: ...a construction du Compteur de D bit FLUX FMT 50 de mat riaux et versions diff rents est conforme aux dispositions r glementaires suivantes 1 EG Richtlinie Maschinen EC Machinery Directive Directive CE...

Page 10: ...10 Talweg 12 75433 Maulbronn Telefon 07043 101 0 Telefax 07043 101 444 Fax International 49 7043 101 555 info flux pumpen de www flux pumpen de...