![FLUQWATER Q75052R Manual Download Page 11](http://html1.mh-extra.com/html/fluqwater/q75052r/q75052r_manual_2310811011.webp)
ERROR
RE ASONS
ERRORSHOOTING
Too small flow rate.
• Inlet obstruction.
• Debris and particles
cause the wear of a
critical part of the pump
which reduces the flow of
the pump.
• Clean the inlet.
• Clean the pump and replace worn
parts.
Close the pump after a short
period of time
• f the water is too dirty,
the pump may stall, and
the heat protector will
cut off the water pump
motor power supply.
• f the water tempera- ture
is too high, the heat
protector will cut off the
water pump motor power
supply.
• Disconnect the main power
supply and clean the water pump.
• Ensure that the maxi- mum water
temperature is not exceeded
35 °C.
4. ERROR SHOOTING
5. CLEAN
Clean the equipment from the outside.
Flush with clean water. Use brush and detergent to remove stubborn pollution. Immerse
the pump into a container with clean water, open it for running a while, and flush it in the
pump.
Storage
If there is a risk of frost, remove equipment and accessories, and clean and store it a
place protected from frost.
Using scope
The pump is mainly used in a basement. When installed at the bottom of the shaft,
the pump prevents seeper in the basement. It can also be used for water supply and
drainage, such as household, agriculture, gardening, pipelines and other suitable
occasions.
ATTENTION!
Before using the pump again, first “clean” to pre- vent any possible dirt residue
which could affect the equipment operation.
Risk for equipment damage!
Frost will destroy electrical appliances and
accessories, because they always contain water.
ATTENTION!