1

1 Safety Precautions 

means items that must be forbidden! Otherwise, it may lead to personal injury or death or 

serious damage.

 means items that must be followed! Otherwise, it may lead to personal injury or property loss.

Please install the unit according

to instructions in this manual. 

Read this manual carefully 

before starting up or checking 

the machine.

For units with wired controller, 

do not connect power supply 

until the wired controller is well 

installed. Otherwise, the wired 

controller cannot be used.

Diameter of power cord must 

be large enough. Damaged 

power cord and connecting 

wire must be replaced by 

specialized electric cable.

Nitrogen must be charged 

according to technical

requirements. 

Make sure the local power 

supply is in accordance with 

units before installation, 

and check the power supply 

carefully.

Installation should be 

performed by dealer or qualified 

technicians. Do not install the 

product by yourself. Improper 

installation may result in water 

leakage, electric shock or fire 

hazard.

Please use specialized 

accessories or parts to carry 

out installation,or water 

leakage, electric shock,fire 

hazard may resulted.

When the installation is

finished, please check and 

make sure the drain pipe, 

pipeline and electric wire are 

all well connected in order to 

avoid water leakage, refrigerant 

leakage, electric shock or fire 

hazard.

R410A refrigerant can produce 

poisonous gas once it meets 

fire, so please ventilate the 

room immediately if refrigerant 

leaks out during installation.

After the power cord is

connected, please install the 

cover of electric box to avoid 

danger.

Short circuit is forbidden. 

Do not cancel the pressure 

switch in case the unit may be 

damaged.

This air conditioner must be 

properly grounded through the 

receptacle to avoid electric 

shock.The grounding wire  

shouldn't be connected with 

gas pipe, water pipe, lightning 

arrester or telephone line.

N

2

Specialized 

Fittings

Specialized

Summary of Contents for FMV-ND100T/A-T

Page 1: ...in it for future reference Multi Variable Air Conditioners Cassette Type Indoor Unit Models FMV ND28T A T FMV ND36T A T FMV ND45T A T FMV ND50T A T FMV ND56T A T FMV ND63T A T FMV ND71T A T FMV ND80T...

Page 2: ......

Page 3: ...and check units please contact our service center We will send specialists to guide the disassembly 6 All graphics in this manual is only for your reference For sales or production reasons these grap...

Page 4: ...llation and Drainage System Testing 10 4 4 Panel installation 12 4 5 Wired controller installation 13 5 Wiring Work 14 5 1 Connection of Wire and Patch Board Terminal 14 5 2 Power Cord Connection 14 5...

Page 5: ...ion should be performed by dealer or qualified technicians Do not install the product by yourself Improper installation may result in water leakage electric shock or fire hazard Please use specialized...

Page 6: ...ditioner continues to operate despite of abnormal condition the unit may be damaged and it may cause electric shock or fire hazard If you use gas heater or petroleum heater in the same room please ope...

Page 7: ...ide Condition Dry Bulb Temp C Wet Bulb Temp C Dry Bulb Temp C Wet Bulb Temp C Rated Cooling 27 19 35 24 Rated Heating 20 15 7 6 Indoor Unit Working Temperature Range 16 C 32 C 2 3 Unit Functions Unit...

Page 8: ...iling opening Arch installation paper Ceiling Articulation Screw Installation hole in the main body Installation hole in the main body Installation hole in the main body 1 Locate the drill hole on cei...

Page 9: ...rference and noise Even though 1m distance is ensure there may be noise if the electric wave is too strong Unit mm H 20 90 140 28 50 Ceiling Wall Floor Wal Model H 210 260 340 56 80 160 315 Fig 3 2 No...

Page 10: ...it 2 Indoor Unit n Outdoor unit1 Outdoor unit 2 Outdoor unit 3 Outdoor unit 4 LO1 L LO1 LO2 LO3 Li1 Li2 Lin n 80 LO2 LO3 Lin Fig 3 3 2 Wire type Total length of communication wire between indoor unit...

Page 11: ...0 1 0 FMV ND140T A T 6 1 0 1 0 FMV ND160T A T 6 1 0 1 0 Notes An all pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in fixed wiring The circuit...

Page 12: ...Suspend the indoor unit 1 Drill bolt holes and install bolts 1 Stick the reference cardboard on the installation position drill 4 holes according to the hole site on the cardboard as shown in fig 4 1...

Page 13: ...ainage pipe by screws 4 Adjust the unit to the right position 5 Check the level of the unit The indoor unit is equipped with build in water pump and float switch verify the levelness of 4 directions b...

Page 14: ...as the drainage pipe During connection insert the end of PVC pipe into the drainage hole and then tighten it with drainage hole and wire binder Can t connect the drainage hole and drainage hole with g...

Page 15: ...revent pipes from sagging install hanger bracket at intervals of 1000 1500mm 1000 1500mm Fig 4 3 4 4 3 3 Test of Drainage System 1 Please test drainage system after electric work is finished Inject ap...

Page 16: ...n 4 4 1 Notices for installation 1 Improper decorative panel installation could cause the following problems Condensation cause water drop dew air leakage Fig 4 4 1 2 Ensure that its clearance free be...

Page 17: ...ver Notices that the connection wire not stuck in the middle of body and panel or may cause air leakage and lead to condensation water drop 4 Tighten 4 screws at each corner of panel respectively fix...

Page 18: ...unit Adjust the static pressure via wired controller according to site circumstance 5 1 Connection of Wire and Patch Board Terminal 1 The connection of wire as shown in fig 5 1 1 1 Strip about 25mm in...

Page 19: ...ng through holes 3 Connect the communication wire to terminal D1 and D2 of indoor 4 bit wiring board as shown in fig 5 3 1 wiring screw terminal board 1 D1 D1 D2 H1 H2 D2 H1 H2 IDU PCB indoor unit pre...

Page 20: ...2 Both IDU and wired controller are equipped with signal receiver and available for wireless control respectively Standard Optional H1 H2 Fig 5 4 3 5 5 Illuminate for Connection of Wired Controller a...

Page 21: ...D2 H1 H2 D1 D2 H1 H2 D1 D2 D1 D2 Fig 5 5 Notes The type of indoor units must be the same if they are controlled by the same wired controller When the indoor unit is controlled by two wired controller...

Page 22: ...ilter 1 Remove the filters from inlet of IDU Use a vacuum cleaner to remove dust If the filters are dirty wash them with warm water and mild detergent and dry the filters in the shade 2 If the unit us...

Page 23: ...so please contact an authorized service center for professional service The following checks prior to contact may save your time and money Phenomenon Troubleshooting The unit can t start Power supply...

Page 24: ......

Reviews: