3-41
Multiplexer
Data acquisition at the VIBRONET multiplexer
For automatic data acquisition at many measurement locations of
the same type or hard-to-access measurement locations, VIBXPERT
and OMNITREND feature the function ‘Multiplexer measurement’.
The respective measurement tasks are processed within a route or
as a machine template.
The measurement locations are combined by the VIBRONET field
multiplexer (VIB 8.306) on one string line and are measured
consecutively.
Only vibration measurements with Current Linedrive accelerom-
eters are possible.
Up to 6 multiplexers with a maximum of 54 measurement locations
are possible on one string line.
To connect VIBXPERT to a multiplexer you need the following:
• Connecting cable, VIB 5.346
• BNC connecting adapter, VIB 5.346 MUX
For RPM-dependent measurements (e.g. phase), you have to install
the sensor (VIB 6.631) at a suitable measurement location. RPM
measurements via multiplexers are not possible.