14
TS44DLX Deluxe Test Set
Users Guide
Pause Duration
The PBX Pause feature lets you insert a delay into
speed dialing numbers. This is required when dialing
out through a system that provides a second dial tone
(such as PBX). Different PBX devices may require
different pause durations to allow enough time for the
second dial tone to be returned. The pause duration
can be programmed.
To change the PBX Pause duration:
1
Set the Talk/Monitor switch to M.
2
Press the STORE/PROG key.
3
Press the PAUSE key.
4
Press a number key to select a pause time. Invalid
entries are ignored. The test set gives a
confirmation tone when the entry is accepted.
Exclusive Receive Only Loud Speaker
In some situations (such as when searching for dial
tone), you may prefer to have the test set’s speaker
remain in Receive Only mode (muted) while
transitioning in and out of Talk mode. To do this, you
may configure the test set to operate with the speaker
exclusively in a receive only mode.
To enable/disable Exclusive Receive Only Loud Speaker
mode:
1
Set the Talk/Monitor switch to M.
2
Press the STORE/PROG key.
3
Press the MUTE key. The test set gives a
confirmation tone.
Speaker Timeout
The speaker draws more current from the battery than
any other circuit on the test set. The battery drains
quickly when the speaker is left on continuously. To
extend battery life, the test set has a timeout function
that automatically turns off the speaker when the test
set is on-hook. A timer starts whenever the test set is
put on-hook. When the test set is off-hook, the timer
will not start.
If the test set is used as a handset in Monitor mode and
if the test set’s receiver has been set to high volume,
the battery is drained very quickly. To avoid this, the
tester has a timeout function for the high volume state
when in Monitor mode. After the timeout, the test set
reverts to low volume.
The speaker timeout duration is programmable while
on-hook and 240 minutes (4 hours) while off-hook. The
off-hook timeout cannot be changed. Remember, the
longer the selected timeout duration the shorter the
battery life.
To change the speaker timeout duration:
1
Set the Talk/Monitor switch to M.
2
Press the STORE/PROG key.
3
Press the SPKR key.
4
Press a number key to select a duration. Invalid
entries are ignored. The test set gives a
confirmation tone when the entry is accepted.
Key
Pause Time
1
2 seconds
2
3 seconds
3
4 seconds (default)
4
5 seconds
Key
Speaker Timeout Duration
1
2 minutes (default)
2
5 minutes
3
10 minutes
4
20 minutes
5
30 minutes
6
40 minutes