Fluke TS 42DLX User Manual Download Page 2

LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke Networks product is warranted to be free from defects in material and workmanship under 
normal use and service. The warranty period for the mainframe is 3 years and begins on the date of purchase. 
Parts, accessories, product repairs and services are warranted for 90 days, unless otherwise stated. Ni-Cad, Ni-
MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories. The warranty 
extends only to the original buyer or end user customer of a Fluke Networks authorized reseller, and does 
not apply to any product which, in Fluke Networks’ opinion, has been misused, abused, altered, neglected, 
contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke Networks 
warrants that software will operate substantially in accordance with its functional specifications for 90 days 
and that it has been properly recorded on non-defective media. Fluke Networks does not warrant that 
software will be error free or operate without interruption.

Fluke Networks authorized resellers shall extend this warranty on new and unused products to end-user 
customers only but have no authority to extend a greater or different warranty on behalf of Fluke Networks. 
Warranty support is available only if product is purchased through a Fluke Networks authorized sales outlet 
or Buyer has paid the applicable international price. Fluke Networks reserves the right to invoice Buyer for 
importation costs of repair/replacement parts when product purchased in one country is submitted for repair 
in another country.

Fluke Networks warranty obligation is limited, at Fluke Networks option, to refund of the purchase price, 
free of charge repair, or replacement of a defective product which is returned to a Fluke Networks 
authorized service center within the warranty period.

To obtain warranty service, contact your nearest Fluke Networks authorized service center to obtain return 
authorization information, then send the product to that service center, with a description of the difficulty, 
postage and insurance prepaid (FOB destination). Fluke Networks assumes no risk for damage in transit. 
Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB destination). 
If Fluke Networks determines that failure was caused by neglect, misuse, contamination, alteration, accident 
or abnormal condition of operation or handling, or normal wear and tear of mechanical components, Fluke 
Networks will provide an estimate of repair costs and obtain authorization before commencing the work. 
Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be 
billed for the repair and return transportation charges (FOB Shipping point).

THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, 
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OR MERCHANTABILITY OR 
FITNESS FOR A PARTICULAR PURPOSE. FLUKE NETWORKS SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY 
CAUSE OR THEORY.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or 
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not 
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other 
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any 
other provision.

4/04-3

Fluke Networks
PO Box 777
Everett, WA 98206-0777
USA

Summary of Contents for TS 42DLX

Page 1: ...TS 42DLX Deluxe Test Set Users Guide PN 2460934 October 2005 2005 Fluke Corporation All rights reserved Printed in China All product names are trademarks of their respective companies...

Page 2: ...or replacement of a defective product which is returned to a Fluke Networks authorized service center within the warranty period To obtain warranty service contact your nearest Fluke Networks authori...

Page 3: ...ing the Test Set in Talk Mode 9 Originating a Call 9 Disconnecting a Call 9 Answering a Call 9 Ground Start 9 Data Safe Practices 10 High Voltage Lockout Operation 10 Configuring Your Test Set 10 Last...

Page 4: ...Set Users Guide ii Maintenance 14 Replacing the Battery 14 Replacing or Relocating the Belt Clip 15 Replacing the Line Cord 15 Removing the Old Line Cord 15 Installing a New Line Cord 16 Accessories 1...

Page 5: ...ities as voice services It is not always easy to tell the difference between data and voice services The TS42DLX Deluxe Test Set incorporates unique patented circuitry that prevents disruption of digi...

Page 6: ...ckout in Talk Mode Software Upgradable Physical Characteristics Housing See Figure 1 The TS42DLX Deluxe Test Set housing is made of high impact plastic The test set provides rugged service and withsta...

Page 7: ...be restricted by local laws The test sets battery compartment makes battery replacement easy See Replacing the Battery on page 14 Note If the test set fails to operate properly first replace the batt...

Page 8: ...circuit in the test set The battery lasts longer if the speaker is used in moderation Audio Controls See Figure 2 The three audio control keys are located on the inside handle of the test set between...

Page 9: ...the MUTE LED will flash VOL Volume Pressing the VOL key switches the sound level of the test set s active receiver between normal and high volume This is true in Monitor mode as well as Talk mode The...

Page 10: ...Dialing Numbers on page 11 FLASH Hook Flash key The FLASH key is used to interrupt loop current for a timed duration The FLASH key only operates when the test set is off hook When pressed the FLASH k...

Page 11: ...ED corresponding to the line polarity will flash for 5 seconds If the loop current is normal the LED will light solid Low loop current may indicate a problem on the line Light Emitting Diodes LEDs All...

Page 12: ...n puts the test set into Monitor mode Using the Test Set in Monitor Mode While in Monitor mode the test set is always on hook The test set draws no direct current from the line and it transmits no sig...

Page 13: ...h to T 6 If talk battery is present the test set will go off hook and draw dial tone Note The test set will not go off hook if the line voltage exceeds 140 V 7 Dial the desired number Disconnecting a...

Page 14: ...ng off hook on a line carrying a high DC voltage can damage the power supply feeding the line To prevent this from occurring the TS42DLX Deluxe provides an automatic high voltage lockout function When...

Page 15: ...red memory location The test set gives a confirmation tone Storing a Number You are Calling 1 Connect the test set to a working telephone line set the TALK MONITOR switch to TALK and receive dial tone...

Page 16: ...e for the second dial tone to be returned The pause duration can be programmed To change the PBX Pause duration 1 Set the Talk Monitor switch to M 2 Press the STORE PROG key 3 Press the PAUSE key 4 Pr...

Page 17: ...volume set to low it draws very little current from the battery The speaker timeout duration is programmable while on hook and 240 minutes 4 hours while off hook The off hook timeout cannot be changed...

Page 18: ...good 9 V alkaline or lithium battery or the test set will not operate properly 1 Disconnect the test set from the line and place on a flat work surface with battery cover up Note Battery cover screws...

Page 19: ...d can be replaced by the user To order a replacement line cord contact your local Fluke Networks authorized distributor See Accessories on page 17 for line cord model numbers WWarning Read all instruc...

Page 20: ...ide of the screw lugs is up see Figure 9 and that the line cord screw lugs are flush against the circuit board Note Do not over tighten screws Over tightening will strip the plastic 2 Fasten the red w...

Page 21: ...order accessories contact your local Fluke Networks distributor Description Fluke Networks Model Number Belt clip lockable both ends P4080248 Belt clip non lockable both ends P4080249 Standard Line Co...

Page 22: ...ories plus one last number redial memory Digit Capacity 23 digits per memory PBX Pause Duration User programmable default of 4 seconds Hook Flash Duration User programmable default of 600 ms Automatic...

Reviews: