![Fluke TAP-DS3E3 Quick Installation Manual Download Page 2](http://html1.mh-extra.com/html/fluke/tap-ds3e3/tap-ds3e3_quick-installation-manual_2310224002.webp)
6-panel Z-fold layout:
CUT
A
T
4.25in fr
om
^^ left edge of this side ^^
C
CO
ON
NN
NE
EC
CT
TIIN
NG
G A
A T
TA
AP
P--D
DS
S3
3E
E3
3 T
TO
O A
A N
NE
ET
TW
WO
OR
RK
K
continued
To connect the TAP-DS3E3 into the network,
refer to Figure 4 below and follow these steps:
IMPORTANT
Do not exceed the maximum length of 122 meters
between end-points.
Figure 4. TAP-DS3E3 simple connectivity diagram
1. Connect a 75Ω coaxial cable from your network
device output (e.g., E3, DS3/T3 or STS-1 network)
to the TAP-DS3E3’s
B IN
BNC port.
2. From the TAP-DS3E3’s
A OUT
port, connect
a separate coaxial cable to your network
device input. At this point, you should have
a two-way connection established between
the TAP-DS3E3 unit and your network.
3. Next, connect a coaxial cable from your
router’s (or other network device) output
port to the TAP-DS3E3’s
A IN
port.
4. From the TAP-DS3E3’s
B OUT
port, connect
a separate cable to your router’s input port.
At this point, you should have a completed
passthrough established between the network
and your router via the TAP-DS3E3 unit.
5. Now, connect a separate cable from the
TAP-DS3E3’s
A TAP
port to a port on your
Network Analysis Tool interface card.
6. Finally, connect a separate cable from the
other port on your Network Analysis Tool
interface card to the TAP-DS3E3’s
B TAP
port.
Single Port Copper Tap
WAN Circuits
T
TA
AP
P--D
DS
S3
3E
E3
3
Q
QU
UIIC
CK
K IIN
NS
ST
TA
AL
LL
LA
AT
TIIO
ON
N G
GU
UIID
DE
E
PN 2530016
August 2005
© 2005 Fluke Networks, Inc. All rights reserved. Printed in USA.
All product names are trademarks of their respective companies.
C
CO
ON
NT
TA
AC
CT
TIIN
NG
G F
FL
LU
UK
KE
E N
NE
ET
TW
WO
OR
RK
KS
S
Visit the Fluke Networks website
at www.flukenetworks.com.
Send email to: [email protected].
For operating assistance, sales, or service in the USA,
call 1-800-283-5853.
From other countries:
• Canada: 1-800-363-5853
• Europe: +44 1923 281 300
• Beijing: +86 (10) 6512-3435
• Japan: +81-3-3434-0181
• Singapore: +65-6738-5655
• Anywhere in the world: +1-425-446-4519
Visit our website for a complete list of phone numbers.
Limited Warranty & Limitation of Liability
Fluke Networks products will be free from defects in
material and workmanship for two years from the date
of purchase. Parts, accessories, product repairs and
services are warranted for 90 days. This warranty
does not cover disposable batteries, cable connector
tabs, cable insulation-displacement connectors, or
damage from accident, neglect, misuse, alteration,
contamination, or abnormal conditions of operation
or handling. Resellers are not authorized to extend
any other warranty on Fluke Networks’ behalf.
To
obtain service during the warranty period, contact
your nearest Fluke Networks authorized service center
to obtain return authorization information, then send
your defective product to that Service Center with a
description of the problem.
THIS WARRANTY IS YOUR ONL
Y REMEDY .
NO OTHER WARRANTIES, SUCH AS FITNESS FOR
A PA
RTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED.
FLUKE NETWORKS IS NOT LIABLE FOR ANY SPECIAL,
INDIRECT , INCIDENT
AL OR CONSEQUENTIAL DAMAGES
OR LOSSES, ARISING FROM ANY CAUSE OR THEORY
.
Since some states or countries do not allow the exclusion
or limitation of an implied warranty or of incidental or
consequential damages, this limitation of liability may
not apply to you.
FLUKE NETWORKS, INC. P .O. BOX 777 EVERETT
, WA
98206-0777 USA
C
CO
OM
MP
PL
LIIA
AN
NC
CE
E T
TE
ES
ST
TIIN
NG
G
CAUTION
Changes or modifications to this unit not expressly
approved by the party responsible for compliance
could void the user’s authority to operate the
equipment.
C
CE
ER
RT
TIIF
FIIC
CA
AT
TIIO
ON
NS
S
This equipment has been tested and found to
meet the radiated and conducted emission limits for
a
Class B
product of
EN 55022
to the
EMC Directive
89/336/EEC
requirements.
This equipment has been tested and found to meet
the immunity levels for
Class 1
, tested to
level 2
for
EN 6100-4-2
, tested to
level 3
for
EN 61000-4-3
,
tested to
level 2
for
EN 61000-4-4
, and tested to
level 3
for
EN 61000-4-5
to the
EN 50082-1
requirements and meets the
Class A
requirements
for
EN 61000-3-2
and
EN 61000-3-3
.
This equipment has completed the Product Safety
Review and found to meet the
Low Voltage Directive
72/23/EEC (1993)
requirements.
Tap Cables
DS3 Network
Router