S
I M P L I
F
I B E R
ENGLISH -
30
center without disturbing
the couplers.
3. Connect the fiber to be
measured between the
launch cables.
4. S
IMPLI
F
IBER
Meter will
immediately report the loss
in dB.
5. Press and hold
to
save the test result.
Method C removes the
effect of the launch cables
and the couplers.
2m Launch Cable
2m Launch Cable
SimpliFiber
Source
METHOD C
Cable Under T
est
SimpliFiber
Meter