Fluke ScopeMeter 190-104 Datasheet Download Page 6

Fluke ScopeMeter 

test tools work 

harder to make 

your job easier

Use the 27,000 points memory of 

ScopeRecord and zoom in for maximum 

detail. 

Cursors and zoom features of the 

Fluke 190 Series help you to analyze 

the captured TrendPlot.

Connect-and-View

 captures even the 

most complex motor drive signals.

See what’s happening with 

fast real-time high resolution 

sampling. ScopeMeter offers a 

sample rate of up to 2.5 GS/s 

with up to 400 ps resolution

Connect-and-View 

triggering for an instant, 

stable display

If you’ve used 

other scopes, you 

know how tricky 

triggering can be. If settings 

are incorrect, results can be 

unstable or incorrect. Connect-

and-View automatically sets up 

correct triggering by recognizing 

signal patterns. Without touch-

ing a button, you get a stable, 

reliable and repeatable display 

of virtually any signal including 

motor drive and control signals. 

It’s especially fast and conve-

nient when you’re measuring a 

number of test points in rapid 

succession.

ScopeRecord

 mode for 

high resolution waveform 

recording up to 48 hours

ScopeRecord

 memory stores up 

to 27,000 data points per chan-

nel, capturing fast intermittents 

and glitches as short as 8 ns. 

(Two sets of multiple-channel 

recordings can be stored for later 

analysis.)

  Stores events like motion 

profiles, UPS, power supply 

and motor start-ups

  With the Stop on Trigger 

mode, the ScopeMeter auto-

matically recognizes a power 

failure and stores the wave-

form data preceding it

  With the waveform  zoom (up 

to 100x) you can look at the 

smallest details, like individual 

power cycles

TrendPlot

 paperless 

recorder—records up to  

16 days to help you find 

intermittent faults

The toughest faults to find are 

those that happen once in a 

while. These intermittents can 

be caused by bad connections, 

dust, dirt, corrosion, or simply 

broken wiring or connectors. 

Line outages, sags or starting 

and stopping of a motor can 

also cause a machine to stop. 

You may not be around when 

it happens, but the Fluke 

ScopeMeter will.

  Plot minimum and maximum 

peak values and average over 

time up to 16 days

  Plot any combination of volt-

ages, amps, temperature, 

frequency and phase for all 

four inputs, all with time and 

date stamp to pinpoint faults

6

Summary of Contents for ScopeMeter 190-104

Page 1: ...The toughest scopes ever built ScopeMeter now takes you into CAT IV environments with four channel testing...

Page 2: ...related measurements on three phases or three axis control systems or simply compare and contrast multiple test points in a circuit under test Features like TrendPlot ScopeRecord and Connect and View...

Page 3: ...category In brief Examples CAT IV Three phase at utility connection any outdoor conductors Refers to the origin of installation that is where low voltage connection is made to utility power Electricit...

Page 4: ...three phase power applications like industrial motors and drives UPS and invert ers for wind energy and diesel locomotive controls for transportation For three axis testing when you need to measure in...

Page 5: ...roblems in industrial systems including Circuit voltage current overloading Attenuation input impedance mismatch Signal fluctuation drift Conditioning circuits signal integrity Test point verification...

Page 6: ...or high resolution waveform recording up to 48 hours ScopeRecord memory stores up to 27 000 data points per chan nel capturing fast intermittents and glitches as short as 8 ns Two sets of multiple cha...

Page 7: ...uously memorizes the last 100 screens As each new screen is acquired the oldest is discarded At any moment you can freeze the last 100 screens and scroll through picture by picture or replay as a live...

Page 8: ...High resolution color display Fast sample rate up to 2 5 GS s with up to 400 ps resolution CAT II 1000 V CAT III 600 V safety rated Plus all the standard features of ScopeMeter including TrendPlot Con...

Page 9: ...Four Channel Industrial Electronics Applications 190 104 190 204 Industrial Network Bus Health Troubleshooting 125 215C and 225C Which ScopeMeter fits you Fluke ScopeMeter Quick Selection Guide Featu...

Page 10: ...Carrying Case SCC290 FlukeView Software and Carrying Case kit BC190 Battery Charger Power Adapter for Fluke 190 Series ScopeMeter BP291 Double Capacity Li ion Battery Pack for Fluke 190 Series II HH29...

Reviews: