Fluke PV350 Instruction Sheet Download Page 3

PV350 English Instruction Sheet 

Page 

mV

87

TRUE RMS MULTIMETER

OFF

mA

A

A

µ

mV

V

V

400mA 

FUSED

!

A

COM

V

mA    A

10A MA

X

FUSED

MIN MAX

RANGE

HOLD 

  

Hz

PEAK

 MIN M

AX

REL

H

P

V

35

0

P

R

E

S

S

U

R

E

 V

A

C

U

M

N

 M

O

D

U

L

E

M

E

T

R

IC

M

E

T

R

IC

O

F

F

k

P

a

.p

s

i

c

m

H

g

.in

H

g

F

LU

K

E

To

pressure/vacuum

input

Sensor

Module

Figure 1. Operation

 

Note 

The Relative or Zero function on your DMM (if available) can 

be used instead of the ZERO potentiometer to zero the meter. 

Refer to the multimeter's user manual for instructions on using 

this function. Zeroing the meter does not affect the module's 

specified accuracy. 

6.

Apply pressure/vacuum to the PV350 and read the DMM display.

When measuring pressure, if the DMM displays OL,

switch the multimeter range from millivolts to dc volts.

Increasing the range to dc volts moves the decimal

position three places to the left (500 psi displays as

0.500 V).

When measuring vacuum the DMM displays a minus sign.

Testing the Battery 

1.

Turn the DMM and the module OFF and connect the PV350 to the

DMM.

2.

Turn the DMM on and set the DMM to the mV dc range.

3.

If the DMM displays less than 100 mV, replace the battery.

How to Replace the Battery 



Warning 

To avoid electrical shock, disconnect the module from all 

devices before opening the case. Be sure to completely 

reassemble the module before attempting to use it. 

Summary of Contents for PV350

Page 1: ...ith min max function become a datalogger capable of measuring peak high and peak low Box Contents Pressure Vacuum Transducer Module 1 4 in male flare to 1 4 in female pipe thread connector 9 V alkaline battery Instruction Sheet Quick Reference Guide Safety Information Warning To avoid eye injury always wear approved safety glasses when working with this instrument To avoid injury from pressure exp...

Page 2: ...sured may result Cleaning Clean the module using a soft cloth and mild soap and water Do not immerse the PV350 in liquids Clean the transducer and connectors after each use with a cleaner appropriate for the liquid or gas connected during measurement Refer to the manufacturer s instructions for the proper cleaning material Measuring Pressure and Vacuum Caution The sensor diaphragm can be damaged b...

Page 3: ...le s specified accuracy 6 Apply pressure vacuum to the PV350 and read the DMM display When measuring pressure if the DMM displays OL switch the multimeter range from millivolts to dc volts Increasing the range to dc volts moves the decimal position three places to the left 500 psi displays as 0 500 V When measuring vacuum the DMM displays a minus sign Testing the Battery 1 Turn the DMM and the mod...

Page 4: ...RANGE HOLD H mA A mV V V OFF A mA A 10A MAX FUSED ZERO SMOOTH Hz RPM DUTY mA A RPM ALERT TRIGGER _ ms PULSE COM 1000V MAX 400mA MAX FUSED DC mV 4000 mV 20 2 4 6 3 8 2 4 6 8 4 V RPM METRIC ENGLISH Z PV500 PRESSURE VACUUM MODULE cmHg inHg kPa psi OFF Figure 3 Pressure for HVAC R Super Heat Measurements 88 AUTOMOTIVE TESTER MIN MAX RANGE HOLD H mA A mV V V OFF A mA A 10A MAX FUSED ZERO SMOOTH Hz RPM ...

Page 5: ...a cm Hg or in Hg Resolution Determined by the resolution of the measuring device RFI Specification Typically 1 error from 80 to 200 MHz at 3 V m Electromagnetic Compatibility EMC International IEC 61326 1 Portable IEC 61326 2 2 CISPR 11 Group 1 Class A Group 1 Equipment has intentionally generated and or uses conductively coupled radio frequency energy that is necessary for the internal function o...

Page 6: ...Standard 9 V Alkaline battery NEDA 1604 IEC 6LR61 Battery Life 300 hours typical Electrical Cable Black PVC will withstand up to 105 C Cable Length 8 ft Pressure Port Connection 1 4 in NPT Connector Brass 1 4 in male flare to 1 4 in female pipe thread List of Replaceable Parts Part Number Description 614487 2813197 2816172 913207 926873 926881 Battery Primary 9 V 0 15 mA Case Bottom PV350 Case Top...

Reviews: