ProSim™ 4
Getting Started
16
General Specifications
Temperature
Operating ............................................................ 10
°
C to 40
°
C (50
°
F to 104
°
F)
Storage ............................................................... -20
°
C to +60
°
C (-4
°
F to +140
°
F)
Humidity
................................................................. 10 % to 90 % non-condensing
Altitude
................................................................... 3,000 meters (9,843 ft)
Size (L x W x H)
..................................................... 18.0 cm x 9.3 cm x 5.5 cm (7.1 in x 3.7 in x 2.2 in)
Display
................................................................... LCD Touch-Screen Color Display
Communication
..................................................... USB Port (for calibration and firmware updates only)
Power
..................................................................... Lithium-Ion rechargeable battery, 10.75 Wh, 3.7 V, 2900 mAh
Battery Charger
..................................................... 110 to 220 Vac, 50/60 Hz input, 6 V/3.5 A output. For best performance, the battery
charger should be connected to a properly grounded ac receptacle.
Battery Life
............................................................ 4 hours (minimum), 40 NIBP cycles typical
Weight
.................................................................... 0.88 kg (1.93 lb)
Safety
..................................................................... IEC 61010-1: Category II, Pollution Degree 2
Electromagnetic Compatibility (EMC)
International ........................................................ IEC 61326-1: Basic Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled
radio frequency energy that is necessary for the internal function of the equipment
itself.
Class A: Equipment is suitable for use in all establishments other than domestic and
those directly connected to a low-voltage power supply network that supplies
buildings used for domestic purposes. There may be potential difficulties in ensuring
electromagnetic compatibility in other environments due to conducted and radiated
disturbances.
Emissions that exceed the levels required by CISPR 11 can occur when the
equipment is connected to a test object.
USA (FCC) .......................................................... 47 CFR 15 subpart B
Summary of Contents for ProSim 4
Page 6: ......
Page 10: ...ProSim 4 Getting Started iv...
Page 12: ...ProSim 4 Getting Started vi...