Fluke PQ Window Instructions Manual Download Page 4

Symbols

Symbol

Description

W

WARNING. RISK OF DANGER.

X

WARNING. HAZARDOUS VOLTAGE. Risk of 
electric shock.

Consult user documentation.

Measurement Category III is applicable to test and 
measuring circuits connected to the distribution 
part of the building’s low-voltage MAINS 
installation.

Measurement Category IV is applicable to test and 
measuring circuits connected at the source of the 
building’s low-voltage MAINS installation.

P

Conforms to European Union directives.

)

Certified by CSA Group to North American safety 
standards.

Conforms to relevant Australian EMC standards.

Type 1

NEMA 250 Enclosure Type. Enclosure suitable for 
indoor use under normal atmospheric conditions. 
Protection against access to hazardous parts and 
ingress of solid foreign objects (falling dirt).

Type 12

NEMA 250 Enclosure Type. Enclosure suitable for 
indoor use. Protection against dust, dripping, and 
light splashing of non-corrosive liquids.

~

This product complies with the WEEE Directive 
marking requirements. The affixed label indicates 
that you must not discard this electrical/electronic 
product in domestic household waste. Product 
Category: With reference to the equipment types in 
the WEEE Directive Annex I, this product is 
classed as category 9 "Monitoring and Control 
Instrumentation" product. Do not dispose of this 
product as unsorted municipal waste.

Summary of Contents for PQ Window

Page 1: ...signal feeds connected you can safely perform voltage and current measurements from outside the enclosure Standard 4 mm safety sockets on the front provides access to the three phases A L1 B L2 C L3 N...

Page 2: ...visit http register fluke com To view print or download the latest manual supplement visit http us fluke com usen support manuals A Warning identifies conditions and procedures that are dangerous to t...

Page 3: ...y with local and national safety codes Use personal protective equipment approved rubber gloves face protection and flame resistant clothes to prevent shock and arc blast injury where hazardous live c...

Page 4: ...tandards Type 1 NEMA 250 Enclosure Type Enclosure suitable for indoor use under normal atmospheric conditions Protection against access to hazardous parts and ingress of solid foreign objects falling...

Page 5: ...Plate installed on PQ Window Frame with Cover Top Plate Decal Set Screws x6 flathead installed x6 panhead Cable Marker Set Current Test Leads x4 Note A single current test lead is available as an opti...

Page 6: ...alcohol and soft cloth Hex key bit 3 16 in not shown Pozidriv screwdriver 1 not shown Figure 2 Tool Requirements Accessories Fuse 2A I17XX BNC M2M Fluke 17XX 4 pin Male to BNC Male Cable 2 m 1x I17XX...

Page 7: ...t hole with the twist drill and use a step drill bit to enlarge the 6 mm 0 2 in pilot hole to 20 mm 0 8 in Or drill a 10 mm 0 4 in pilot hole and then enlarge the hole to 22 5 mm 0 875 in with a Punch...

Page 8: ...gh Box from the rear to the front plate Fasten the front plate with the 6 panhead screws 5 If the space for the standard configuration is too small remove the top plate and rotate in 90 increments to...

Page 9: ...rrule for stranded wires 4 Push the wire into the circular opening of the terminal Note To remove the wire push a 3 5 mm slotted screwdriver into the rectangular opening of the terminal and pull out t...

Page 10: ...ker 1 from the set see Figure 1 item on both ends of the cable for phase A L1 Continue with marker 2 for phase B L2 and marker 3 for phase C L3 and N and Earth Ground 5 Refer to local regulations to p...

Page 11: ...nt Category rating of the measurement instrument and accessories matches or exceeds the rating of the installation 3 Use the current test lead to connect the current measurement signal output of the P...

Page 12: ...ase Make sure the circuit is secure against reenergizing of the installation Use only specified replacement fuses Fuse Replacement To replace a fuse 1 De energize the installation 2 Loosen the four ca...

Page 13: ...x D 148 mm x 370 mm x 19 mm with cover opened Inside 140 mm x 158 mm x Di W x H x D Di 58 thickness of panel door in mm Supported Electrical Enclosures UL 50 NEMA Environmental Enclosure Type 1 Type...

Page 14: ...le batteries or damage from accident neglect misuse alteration contamination or abnormal conditions of operation or handling Resellers are not authorized to extend any other warranty on Fluke s behalf...

Page 15: ...reserved x Manual Title PQ400 Instructions Part Number 4954885 Supplement Issue 1 Print Date October 2018 Issue Date 3 19 Revision Date 1 2 19 Page Count 1 This supplement contains information necessa...

Page 16: ...e wire gauge used for the voltage inputs to the Product On the 13th page under Environment replace the Humidity with Humidity 10 to 90 non condensing in dependency of temperature according to IEC 6072...

Reviews: