![Fluke Performance Series User Manual Download Page 66](http://html.mh-extra.com/html/fluke/performance-series/performance-series_user-manual_2309419066.webp)
Ti90, Ti95, Ti100, Ti105, Ti110, Ti125, TiR105, TiR110, TiR125
Users Manual
60
Detailed Specifications
Temperature Measurements
Temperature Range (not calibrated below -10
°
C)
Ti90, Ti95, Ti100, Ti105, Ti110 ....................... -20
°
C to +250
°
C
Ti125 ............................................................... -20
°
C to +350
°
C
TiR105, TiR110, TiR125 .................................. -20
°
C to +150
°
C
Accuracy ..............................................................
±
2
°
C or 2 % (whichever is greater) at
25
°
C ambient
Measurement Modes ........................................... Smooth Auto-Scaling and Manual
Scaling
On-screen Emissivity Correction ......................... all models
Imaging Performance
Field of View
Ti100, Ti105, Ti110, Ti125, TiR110, TiR125 ... 31
°
x 22.5
°
Ti95 ................................................................. 26
°
x 26
°
Ti90 ................................................................. 19.5
°
x 26
°
Spatial Resolution
Ti100, Ti105, Ti110, Ti125, TiR110,
TiR125 (IFOV) ................................................. 3.39 mRad
Ti90, Ti95 (IFOV) ............................................. 5.6 mRad
Minimum Focus Distance
Ti100, Ti105, TiR105 ....................................... 122 cm (approx. 48 in)
Ti90, Ti95 ........................................................ 46 cm (approx. 18 in)
Ti110, Ti125, TiR110, TiR125 ......................... 15 cm (approx. 6 in)
Focus
Ti90, Ti95, Ti100, Ti105, TiR105 ..................... Focus-free
Ti110, Ti125, TiR110, TiR125 ......................... IR-OptiFlex™ focus
Image Capture or Refresh Rate
Ti90, Ti95, Ti100, TiR105, TiR110, TiR125 ..... 9 Hz
Ti105, Ti110, Ti125 ......................................... 9 Hz or 30 Hz (factory set)
Detector Type (Focal Plane Array, uncooled microbolometer)
Ti100, Ti105, Ti110, Ti125, TiR110, TiR125 ... 160 X 120
Ti95 ................................................................. 80 x 80
Ti90 ................................................................. 80 x 60
Thermal Sensitivity (NETD)
Ti90 ................................................................. 150 mK
Ti95, Ti100, Ti105, Ti110, Ti125 .....................
≤
100 mK (0.1
°
C at 30
°
C target
temperature)
TiR105, TiR110, TiR125 ..................................
≤
80 mK (0.08
°
C at 30
°
C target
temperature)
Shop for Fluke products online at:
1.888.610.7664
www.
MyFlukeStore
.com