Twisted Pair Test Results
The following figures show typical test results for twisted
pair cabling.
Open on Twisted Pair Cabling
Figure 6 shows an open on wire 4.
Notes
If only one wire in a pair is open and a wiremap
adapter or remote ID locator is not connected, both
wires are shown as open.
The warning icon (
) does not appear if both
wires in a pair are open because open pairs are
normal for some cabling applications.
The three segments shown for the wire pair length indicate
the open is approximately 3/4 the distance to the end of the
cabling. The cable length is 75.4 m.
To see the distance to the open, use
or
to view the
individual result for the wire pair. See page 20.
egk05.eps
Figure 6. Open on Twisted Pair Cabling