Safety Instructions 

In this instruction sheet, a 

Warning

 identifies conditions and 

actions that pose hazard(s) to the user. A 

Caution

 identifies 

conditions and actions that may damage the calibrator or the test 
instruments. 

WX

 Warning 

To avoid electric shock or personal injury: 

 

If the Probes are used in a manner not 
specified in these operating instructions, 
protection provided by the Probes may be 
impaired. 

 

Use the Probes only if qualified. 

 

Use caution during installation and use of the 
Probes; high voltages and currents may be 
present in circuit under test. 

 

Have maintenance performed by only qualified 
service personnel. 

 

Protect the Probes against water and 
humidity. 

 

Wear protective clothing and gloves as 
required. 

 

Do not install this product on live conductors. 
Always de-energize the circuit under test 
before installing the flexible measuring head. 

 

Always inspect the electronics unit, 
connecting cable, and flexible measuring head 
for damage before using the Probe. 

 

Do not use the Probe if damaged. 

 

Always connect Probe to display device 
before installing the flexible measuring head. 

 

Never change batteries while measurement 
head is installed on conductor. 

 

Never connect or disconnect the external 
power supply while the measurement head is 
installed on a conductor. 

 

Use only the provided original or specified 
accessories. 

 

Adhere to local and national safety codes. 
Individual protective equipment must be used 
to prevent shock and arc blast injury where 
hazardous live conductors are exposed. 

 

CAT III equipment is designed to protect 
against the transients in the equipment in 
fixed equipment installations, such as 
distribution panels, feeders and short branch 
circuits, and the lighting systems in large 
buildings. 

Summary of Contents for i6000s Flex-24

Page 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Page 2: ...to the current being measured The Probes provide full scale direct readings for 60 A 600 A and 6000 A Symbols The following table shows the symbols used on the product and or in this manual Symbol Des...

Page 3: ...uctors Always de energize the circuit under test before installing the flexible measuring head Always inspect the electronics unit connecting cable and flexible measuring head for damage before using...

Page 4: ...reading Noise 8 mV ac rms 60 A 2 mV ac rms 600 6000 A Frequency Range 10 Hz to 50 kHz 3 dB Phase error 1 45 65 Hz 10 at 20 kHz Position sensitivity with cable 25 mm from the coupling 2 of range Exter...

Page 5: ...ug adapter Operating Temperature 20 C to 90 C 4 to 194 F head 20 C to 85 C 4 to 185 F electronics Storage Temperature 40 C to 105 C 40 to 221 F head 20 C to 85 C 4 to 185 F electronics Operating Humid...

Page 6: ...wf0001 eps A Measuring head B Measuring head coupling C Head output cable D Enclosure E Power on Range selector F Battery low indicator G Power on indicator H Output cable I Safety BNC connector J Ext...

Page 7: ...move the battery cover 3 Install the batteries ensuring that correct polarity is observed 4 Replace the battery cover and turn the battery lock until the dot aligns with the lock symbol External Power...

Page 8: ...m the nearby conductors WX Warning To avoid electric shock or injury Do not use the flexible current Probes to measure bare conductors unless wearing protective clothing suitable for high voltage work...

Page 9: ...is Fluke product will be free from defects in material and workmanship for one year from the date of purchase This warranty does not cover fuses disposable batteries or damage from accident neglect mi...

Reviews: