Fluke i3000s Flex Series Instruction Sheet Download Page 1

®

 

i3000s

 

AC Current Clamp 

Instruction Sheet 

Introducing the i3000s 

The i3000s is a clamp-on AC Current Clamp for use with 
oscilloscopes and multimeters with banana input using the supplied 
Dual Banana to BNC Adapter. The clamp is optimized for 
measurement on power distribution systems. 

Unpacking 

The following items should be included in your Current Clamp box: 

 Current 

Clamp 

 

Dual Banana to BNC Adapter (model PM9081/001) 

 

Instruction Sheet (this paper) 

Check the contents of the shipping box for completeness. If 
something in the box has been damaged or missing, contact your 
distributor or the nearest FLUKE sales or service office immediately. 

Safety Information 

 

  

Read First: Safety Information. 

To ensure safe operation and service of the 
current clamp, follow these instructions: 

 

 

Read the operating instructions before use and follow all 
safety instructions. 

 

Use the Current Clamp only as specified in the operating 
instructions, otherwise the clamp’s safety features may 
not protect you. 

 

Adhere to local and national safety codes. Individual 
protective equipment must be used to prevent shock and 
arc blast injury where hazardous live conductors are 
exposed. 

 

Do not hold the Current Clamp anywhere beyond the 
tactile barrier, see Figure 8. 

 

Before each use, inspect the Current Clamp. Look for 
cracks or missing portions of the clamp housing or output 
cable insulation. Also look for loose or weakened 
components. Pay particular attention to the insulation 
surrounding the jaws. 

 

Check the magnetic mating surfaces of the clamp jaws; 
these should be free of dust, dirt, rust and other foreign 
matter. 

 

Never use the clamp on a circuit with voltages higher than 
600 V CAT III. 

 

CAT III equipment is designed to protect against 

transients in equipment in fixed equipment 
installations, such as distribution panels, feeders and 
short branch circuits, and lighting systems in large 
buildings. 

 

Use extreme caution when working around bare 
conductors or bus bars. Contact with the conductor could 
result in electric shock. 

 

Use caution when working with voltages above 60 V dc, 
30 V ac rms or 42

 

V ac peak. Such voltages pose a shock 

hazard. 

Symbols 

 

May be used on HAZARDOUS LIVE conductors. 

 

Product is protected by double insulation. 
 

 

Risk of Danger. Important information. See 
Instruction Sheet. 

 

Risk of Electric Shock. 

 

Conforms to relevant European standards. 

 

Earth ground 

 

Specifications 

SAFETY 

 

 

Input jaws &  
Output float voltage 

Complies with European 
standards EN/IEC 61010-1 
2nd Edition & EN/IEC 61010-
02-032 for 600V CAT III, 
pollution degree 2.  

 

 

CE Conformity 

EN/IEC 61010-02-032 

 

 

ELECTRICAL SPECIFICATIONS 

All Electrical Specifications are valid at the following reference 
conditions: 

 

 

Ambient temperature 

23±3°C (73±3°F) 

 

Relative Humidity 

0 to 85% 

 

Frequency 

48 to 65 Hz 

 

Continuous external field 

< 40 A/m 

 

Load impedance 

1 M

 // 47 pF 

 

The current may not contain any DC component 

 

No influence from adjacent currents 

 

The conductor must be centered within the jaw aperture 

 

 

 

Current Ranges 

 

30A 300A 3000A 

Measuring range 

1 to 30A ac 

1 to 300A ac 

1 to 3000 A ac 

Crest factor * 

up to 3 

up to 3 

up to 3 

Maximum non-
destructive current: 

 

 

 

 continuous  36A 360A 2400A 

 30min.+30min.

stop 

  2800A 

 5min.+30min. 

stop 

  4000A 

Output signal 

10 mV/A 

1 mV/A 

0.1 mV/A 

Basic accuracy 

2% of reading 
+ 0.1A 

2% of reading 
+ 0.5A 

2% of reading 
+ 2A 

Additional errors: 

 

 

 

 with 

temperature  
(-10 to +50°C) 

0.02%/°C 0.02%/°C 0.02%/°C 

 

with position of 
conductor in 
the clamp 
window 

1% + 0.1A 

1% + 0.1A 

1% + 0.1A 

 with 

adjacent 

conductor 

0.005A/A 0.005A/A 0.005A/A 

 with 

frequency 

(10Hz to 100 
kHz) 

See Figure 1  See Figure 2  See Figure 3 

Phase shift 

20° @ 2A 
10° @ 8A 
5° @ 30A 
See Figure 4 

3° @ 20A 
1.5° @ 80A 
1° @ 300A 
See Figure 5 

3° @ 200A 
1.5° @ 800A 
1° @ 3000A 
See Figure 6 

*  This is the maximum permissible ratio between the peak value 

of a superimposed transient and the ac rms value. 

 

Bandwidth (-3dB) 

(see Figure 7 for derating)

10 Hz to 100 kHz 

 

 

GENERAL 

 

Clamp Dimensions 

310 x 120 x 48 mm  
(12.2 x 4.7 x 1.9 in) 

Weight 

1200 g  (42.3 oz) 

Cable length 

2.1 m (82.6 in) 

Maximum conductor size 

 64 mm (2.5 in) 

Maximum Jaw Opening 

90 mm (3.5 in) 

Temperature 

Operating 
Non-operating 

 
-10 to +50°C (+14 to +122°F) 
-40 to + 85°C (-40 to +185°F) 

Relative Humidity 

Operating 
 
Non-operating 
 

 
0 to 85%, up to +35°C (+95°F) 
0 to 75%, up to +50°C (+122°F) 
0 to 85%, up to -10°C (+14°F) 
0 to 75%, up to +85°C (+185°F) 

Altitude 

Operating 
Non-operating 

 
to 2000 m (6500 ft) 
to 12000 m (40000 ft) 

 

FREQUENCY RESPONSE 

30A Range 

 

Figure 1. Frequency Response @ 10A 

300A Range 

 

Figure 2. Frequency Response @ 10A 

3000A Range 

 

Figure 3. Frequency Response @ 100A 

 

October 1997,  Rev.3, 08/05 

© 1997 -2005  Fluke Corporation. 
All rights reserved.  
Printed in the Netherlands  
All product names are trademarks 
of their respective companies. 