Fluke EBC290 Instruction Sheet Download Page 2

 

Symbols 

 

Risk of Danger. Important information. See 
Instruction Sheet.

 

 

Do not dispose of this product as unsorted municipal 
waste. Go to Fluke's website for recycling 
information. 

 

Conforms to relevant European standards. 

 

Specifications 

Electrical Specifications

 

 

Power connection 

BC190 or BC430 

Adapter requirement 

17.8 V / 0.84 A 

Input current limitter 

714 mA 

±

5% 

Input voltage range 

15 to 23 V 

Batteries BP291 
capacity 52 

Wh 

Charge time 

5.5 Hours 

Charge operating range 

0 to 45°C (determined by battery)  

Charge disable protection 
(smbus controlled) 

54°C 

±

3°C battery temp 

(determined by battery) 

Charge disable protection 
(hardware controlled) 

58°C 

±

3°C battery temp 

(determined by battery) 

General Specifications

 

Temperature: 
Operating 
 
Non Operating (Storage) 

 

°

C to +45 

°

C (determined by 

battery) 
-20

°

C to +60 

°

Maximum Relative Humidity 
Non Operating (Storage): 
 
Operating: 
 

 

  0 ... 10 

°

 

 

10 ... 30 

°

 

 

30 ... 40 

°

 

 

40 ... 45 

°

 
No precipitating (noncondensing) 
Recovery time two hours 
 
No precipitation (noncondensing) 
95 

±

 5 % 

75 

±

 5 % 

45 

±

 5 % 

Emission and Immunity 

EN-IEC-61326-1 
(first edition 2005).  

Height x Width x Depth 
(excluding battery) 

44 x 65 x 100 mm 

Weight 85 

 
 

Using the EBC290 

To use the EBC290, follow these instructions (Refer to Figure 
1): 
1. 

Connect the Power Adapter BC190 (or BC430) to a mains 
outlet and insert the DC plug of the Power Adapter into the 
External Charger. 

1

3

4

2

 

 

Fig. 1 

 

2. 

Insert the battery to be charged into the External charger. 
Take careful notice of the correct placement of the battery. 

3. 

Observe the green LED indicator: 
- Slow flashing indicates that the battery is charging. 
- Continuously on indicates that the battery is fully 
charged. 
- Fast flashing indicates a battery error. 

4. 

During the charging process the number of segments to 
turn on in the battery display will increase over time. All 
segments on indicates that the battery is charged to 100 % 
of its present capacity.  

 

Cleaning 

Before cleaning, separate the product from Power Adapter and 
Battery. 
Clean the EBC290 with a damp cloth and a mild detergent. Do 
not use abrasives, solvents, or alcohol. 

Troubleshooting 

In case of an error, the green LED in the Charger will flash at a 
high rate which indicates a possible battery problem. When 
available, insert another battery to determine is the error is 
caused by the battery or by a defective charger. 
 

 

All manuals and user guides at all-guides.com

Reviews: