Appendix B: Fiber Test Method Names
Industry standards use different names for equivalent fiber
test methods. Table B-1 shows the names used in this
manual and by four common industry standards for the
three fiber test methods.
Table B-1. Test Method Names
Link End Connections
Included in Loss Results
This
Manual
TIA/EIA-526-14A
(multimode)
TIA/EIA-526-7
(singlemode)
IEC 61280-4-1
(multimode)
IEC 61280-4-2
(singlemode)
1 connection
2 Jumper
Method A
Method A.2
Method 1
Method A2
2 connections
1 Jumper
Method B
Method A.1
Method 2
Method A1
None
3 Jumper
Method C
Method A.3
Method 3
Method A3