DTX Series CableAnalyzer
Technical Reference Handbook
7-48
Using Manual OTDR Mode
Note
Typically, you should use Auto OTDR mode when
certifying cabling with the OTDR.
Manual OTDR mode lets you optimize the OTDR trace for
viewing specific events.
To select Manual OTDR mode, turn the rotary switch to
AUTOTEST, press
L
Change Test; then select Manual.
Table 7-5 describes the settings you can change in manual
OTDR mode and how the settings affect the trace. You can
access these settings on the Fiber OTDR tabs in Setup.
Tip: To see the settings used for an OTDR test, press
K
View Events on the OTDR Results screen, press
L
View
Details; then press
J
OTDR Settings. The settings used
may be slightly different from the nominal values selected
on the OTDR tab.
Table 7-5. Manual OTDR Settings
Setting
Description and Selection Guidelines
Range
The range setting determines the maximum distance shown on the trace.
Auto: The tester selects the range that is nearest to, but not less than the end of the fiber. These
ranges are not limited to the fixed ranges provided.
Manual range selections: You select the range. Typically, you should select the range that is nearest
to, but not less than, the distance to the event you want to study. If the tester does not correctly
identify the end event, run the OTDR test again using the next higher range.
Summary of Contents for DTX-1800
Page 4: ......
Page 18: ...DTX Series CableAnalyzer Technical Reference Handbook xiv ...
Page 132: ...DTX Series CableAnalyzer Technical Reference Handbook 4 8 ...
Page 158: ...DTX Series CableAnalyzer Technical Reference Handbook 6 14 ...
Page 270: ...DTX Series CableAnalyzer Technical Reference Handbook 8 62 ...
Page 284: ...DTX Series CableAnalyzer Technical Reference Handbook 10 10 ...
Page 304: ...DTX Series CableAnalyzer Technical Reference Handbook 11 20 ...
Page 372: ...DTX Series CableAnalyzer Technical Reference Handbook A 8 ...
Page 374: ...DTX Series CableAnalyzer Technical Reference Handbook B 2 ...