DTX Series CableAnalyzer
Technical Reference Handbook
7-22
Progress Screen for Extended Test Times
When the test time per wavelength exceeds 21 seconds, the
tester shows the developing trace along with the progress
indicator. Figure 7-11 shows an example of this screen. The
tester updates the trace as measurement averaging
proceeds.
To end a Manual OTDR test and see the results after the
next trace update, press
K
Stop Averaging. For dual-
wavelength tests, press
K
twice –once for each
wavelength. This softkey is not available for Auto OTDR
tests.
amd92.bmp
Figure 7-11. Progress Screen for Extended Test Times