background image

Quick Start Guide

CopperPro 990 Loop Tester

Powering up your CopperPro.

The green       key in the lower right hand corner of the key pad functions as both an
Off and On button. Press and hold briefly to turn the set on. A screen showing infor-
mation about the 990 hardware and software will be displayed briefly. The main menu
will appear. To turn the set off, press the key again.

Running the Auto Tests.

CopperPro’s main screen displays up to four AutoTests, depending on the model and
options you have. To highlight a test, use the        and        keys. To adjust the set-
up for the test, highlight it, and select the Setups menu option. To run the test, press
the          key.

Running individual tests like voltage 
or resistance.

Individual tests are available in the
three Toolboxes displayed at the 
bottom of the display. Press the key
beneath the menu choice to enter a
toolbox. Then use the arrow keys to
select the test you want to run. To 
alter the setups for the test, first 
highlight the test, then select the
Setups menu option.

Measuring loop 
current.

Connect the black (tip), red (ring)  
and green (ground) leads to an active
pair.

Select the 

POTS Toolbox

and highlight

Dial-up Tests

and press         . Select

Loop Cur. & Gnd 

. CopperPro will go

off-hook, measure loop current and
ground resistance between the central
office and the point of testing.

N E T W O R K

S U P E R

V I S I O N

CopperPro’s primary navigation keys

Reviews: