Fluke 80TK Instruction Sheet Download Page 4

80TK-4012

MP101

MP102

 

80TK Schematic Diagram

 

Replaceable Parts 

Ref Des

PN

Description

 

2814488 CASE 

TOP 

 

2814495 CASE 

BOTTOM 

 

735860 COVER 

SWITCH 

 

735944 SHIELD, 

BOTTOM 

 

735910 SHIELD, 

TOP 

 

735928 SHIELD 

CONTACT 

 

747501 SCREW,SCREW,PH,PO,STL,4-40,.250 

MP101 

202470  CURRENT SHUNT SHROUD (RED) 

MP102 

202447  CURRENT SHUNT SHROUD (BLACK) 

AR1 

802691  IC,OP AMP,TLC271A,PROGRAMMABLE,LOW POWER,SO8 

BT1 696534 

BATTERY,PRIMARY 

,BATTERY,9V,0-15MA 

C1 C2 

942529  CAPACITOR,SMR,CAP,CER,0.1UF,+-10%,25V,X7R,0805 

C3 942552 

CAPACITOR,SMR,CAP,TA,1UF,+-20%,20V,3216 

C4 650223 

CAPACITOR,SMR,CAP,TA,10UF,+-20%,10V,3216 

CR1 CR4 

830489  DIODE,BAS16,SMR,DIODE,SI,75V,250MA,SOT-23 

CR2 876529 

DIODE,BAT54,SMR,DIODE,SI,SCHOTTKY,30V,200MA,SOT-23 

J1 J2 

735993  80TK-8008,CONTACT, THERMOCOUPLE 

MP1 

1276793  80TK-3012,80TK - PCB SM_PIH 

P1 P2 

736033  80TK-8009,PLUG,BANANA 

Q1 Q2 Q4 

742676  NPN,MMBT3904,SMR,TRANSISTOR,SI,NPN,60V,350MW,SOT-23 

Q3 820902 

NPN,MMBT5089,SMR,TRANSISTOR,SI,NPN,30V,200MW,SOT-23 

Q5 Q6 

820910  PNP,MMBT5087,SMR,TRANSISTOR,SI,PNP,50V,225MW,SOT-23 

R1 802725 

RESISTOR,CERMET,22M,+-1%,0.1W,400PPM,0805,TAPE 

R10 943006 

RESISTOR,CERMET,2.1K,+-1%,0.1W,100PPM,0805,TAPE 

R11 913731 

RESISTOR,SMR,RES,CERM,22.1K,+-1%,100PPM,1206 

R12 802675 

RESISTOR,SMR,RES,MF,18.2K,+-0.1%,0.1W,25PPM,0805 

R13 802683 

RESISTOR,SMR,RES,MF,22.1K,+-0.1%,0.1W,25PPM,0805 

R14 R18 

867296  RESISTOR,SMR,RES,CERM,698K,+-1%,.125W,100PPM,1206 

R15 802717 

RESISTOR,CERMET,1.82M,+-1%,0.1W,400PPM,0805 

R16 928085 

RESISTOR,SMR,RES,VAR,CERM,200K,+-25% 

R17 821447 

RESISTOR,SMR,RES,CERM,4.22K,+-1%,.125W,100PPM,1206 

R19 943659 

RESISTOR,CERMET,10M,+-1%,0.1W,400PPM,0805,TAPE 

R2 R20 

928866  RESISTOR,SMR,RES,CERM,100K,+-1%,0.1W,100PPM,0805 

R21 928767 

RESISTOR,SMR,RES,CERM,4.99K,+-1%,0.1W,100PPM,0805 

R22 928754 

RESISTOR,SMR,RES,CERM,2.43K,+-1%,0.1W,100PPM,0805 

R23 806240 

RESISTOR,SMR,RES,CERM,1.2M,+-5%,.125W,200PPM,1206 

R24 802709 

RESISTOR,CERMET,4.12M,+-1%,0.1W,400PPM,0805 

R3 802659 

RESISTOR,SMR,RES,MF,750K,+-0.25%,0.1W,50PPM,0805 

R4 106937 

RESISTOR,SMR,RES,VAR,CERM,100,+-20%,0.25W 

R5 802782 

RESISTOR,SMR,RES,VAR,CERM,1K,+-20%,0.25W 

R6 927426 

RESISTOR,SMR,RES,CERM,182K,+-1%,.125W,100PPM,1206 

R7 876441 

RESISTOR,SMR,RES,CERM,604K,+-1%,.125W,100PPM,1206 

R8 802444 

RESISTOR,SMR,RES,MF,10K,+-0.1%,0.1W,50PPM,0805 

R9 802667 

RESISTOR,SMR,RES,MF,442K,+-0.1%,0.1W,25PPM,0805 

S1 740225 

SWITCH,SWITCH,SLIDE,DPTT 

VR1 

930065  BIPOLAR 4040,SMR,IC,V REF,SHUNT,2.5 V,1%,150 PPM,SOT23 

LIMITED WARRANTY & LIMITATION OF LIABILITY 

Each Fluke product is warranted to be free from defects in material and workmanship 
under normal use and service.  The warranty period is one year and begins on the date 
of shipment.  Parts, product repairs and services are warranted for 90 days. This 
warranty extends only to the original buyer or end-user customer of a Fluke authorized 
reseller, and does not apply to fuses, disposable batteries or to any product which, in 
Fluke's opinion, has been misused, altered, neglected or damaged by accident or 
abnormal conditions of operation or handling.  Fluke warrants that software will operate 
substantially in accordance with its functional specifications for 90 days and that it has 
been properly recorded on non-defective media.  Fluke does not warrant that software 
will be error free or operate without interruption.  
 
Fluke authorized resellers shall extend this warranty on new and unused products to 
end-user customers only but have no authority to extend a greater or different warranty 
on behalf of Fluke. Warranty support is available if product is purchased through a 
Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke 
reserves the right to invoice Buyer for importation costs of repair/replacement parts 
when product purchased in one country is submitted for repair in another country. 
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, 
free of charge repair, or replacement of a defective product which is returned to a Fluke 
authorized service center within the warranty period. 
 
To obtain warranty service, contact your nearest Fluke authorized service center or 
send the product, with a description of the difficulty, postage and insurance prepaid 
(FOB Destination), to the nearest Fluke authorized service center.  Fluke assumes no 
risk for damage in transit.  Following warranty repair, the product will be returned to 
Buyer, transportation prepaid (FOB Destination).   If Fluke determines that the failure 
was caused by misuse, alteration, accident or abnormal condition of operation or 
handling,  Fluke will provide an estimate of repair costs and obtain authorization before 
commencing the work.  Following repair, the product will be returned to the Buyer 
transportation prepaid and the Buyer will be billed for the repair and return 
transportation charges (FOB Shipping Point). 
 
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU 
OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT 
LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR 
A PARTICULAR PURPOSE.  FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, 
INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, 
INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY 
OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY. 
 
Since some countries or states do not allow limitation of the term of an implied warranty, 
or exclusion or limitation of incidental or consequential damages, the limitations and 
exclusions of this warranty may not apply to every buyer.   If any provision of this 
Warranty is held invalid or unenforceable by a court of competent jurisdiction, such 
holding will not affect the validity or enforceability of any other provision. 
 
 

1.888.475.5235

[email protected]

Fluke

-

Direct

.com

www.valuetronics.com

Summary of Contents for 80TK

Page 1: ...e is suspected of interfering with this module either turn off the transmitter or increase the separation between the transmitter and the module Environmental Ambient Operating Range 0 to 50 C Storage Temperature 40 to 60 C 40 to 140 F Humidity 0 to 90 0 to 35 C 0 to 70 35 to 50 C Basic Accuracy 23 5 C Calibration Applies for one year after purchase or recalibration RANGE ACCURACY of reading degre...

Page 2: ...illivolts the range has i e 320 C or F if the millivolt range reads 320 mV 3 Use the dc volt setting and ignore the decimal for higher temperatures than can be accommodated by the millivolt range Less resolution is available when using the volt range XWWarning To avoid electrical shock if connecting wires to the input screws make sure the thermocouple is removed from the measurement surface Comple...

Page 3: ...ter position 7 Adjust R16 until the reading on the multimeter matches the reading on the mercury reference thermometer 0 2 F Note If the mercury reference thermometer displays C use the following conversion to get F 9 5 temp in C 32 temp in F 8 Set 80TK switch to the OFF position Remove 80TK from multimeter and remove any connections to the 80TK thermocouple input terminals 9 Reassemble the 80TK 1...

Page 4: ...s not apply to fuses disposable batteries or to any product which in Fluke s opinion has been misused altered neglected or damaged by accident or abnormal conditions of operation or handling Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non defective media Fluke does not warrant that so...