Infrared Thermometers
566/568 Display
11
Table 4. Nominal Surface Emissivity (566/568)
Material
Value Material Value
Default****
0.95 Glass
(plate)
0.85
Aluminum*
0.30 Iron*
0.70
Asbestos 0.95
Lead*
0.50
Asphalt 0.95
Oil
0.94
Brass*
0.50
Paint
0.93
Ceramic 0.95
Plastic**
0.95
Concrete 0.95
Rubber 0.95
Copper*
0.60 Sand
0.90
Food - Frozen
0.90
Steel*
0.80
Food - Hot
0.93
Water
0.93
Wood ***
0.94
* Oxidized
** Opaque, over 20 mils
*** Natural
**** Factory Setting
Highlighted items may also be found in the emissivity table built into the thermometer.
°
C and
°
F
To toggle between
°
C (Celsius) and
°
F (Fahrenheit) measurements, press the
Menu
softkey until
°
C
or
°
F
appears
as the left softkey function. Press the
corresponding softkey to change between the measurements.
Min, Max, Avg, Differential
The thermometers can measure minimum (MIN), maximum (MAX), average
(AVG), or differential (
Δ
) temperatures each time a reading is taken. These
values are not shown if a thermocouple is plugged into the thermometer.
To turn on the Min Max mode:
1. Press the
Menu
softkey until
MnMx
(Min Max) appears as the left softkey
function.
2. Press the
MnMx
softkey.
The display shows the present reading, maximum and minimum readings, and
the emissivity setting.
To turn on the Avg/Dif mode:
1. Press the
Menu
softkey until
Avg
appears as the right softkey function.
2. Press the
Avg
softkey.
The display shows the present reading, average reading, the differential reading
between max and min (designated by
Δ
), and the emissivity setting.
Shop for Fluke products online at:
1.877.766.5412
www.
MyFlukeStore
.com