6/7
Pythagoras
See drawing
G:
Â
Press key
8
three times.
The Pythagoras symbol appears on the
display.
Â
Press key
4
and measure the first distance
(diagonal measurement).
Â
Press key
4
and measure the second distance
(horizontal measurement).
The device displays the result in the summary
row and the respective measured distance to the
next measurement in the second row.
Troubleshooting
Â
If the message
Error
does not disappear
after switching on the device repeatedly,
please contact the retailer.
Â
If the message
InFo
appears with a number,
observe the instructions in the following
table.
Technical data
* under favorable conditions (good target
surface, room temperature) up to 10 m (33ft).
Under unfavorable conditions such as bright
sunlight, a very weakly reflecting target surface
or large temperature fluctuations, the deviation
can rise by ± 0.25 mm/m (±0.01 in) for
distances over 10 m (33 ft).
Electromagnetic compatibility
(EMC)
Despite the compliance with all requirements of
the corresponding directives and norms, a
disturbance of other devices is possible.
No.
Cause
Remedy
204 Calculation error
Perform measurement
again.
252 Temperature too high
Let the device cool
down.
253 Temperature too low
Warm the device up.
255 Reception signal too
weak, measuring time
too long
Change target surface
(e.g. white paper).
256 Input signal too high
Change target surface
(e.g. white paper).
257 Measuring error, too
much background light
Shadow the target
area.
258 Measurement outside
of the measuring range
Mind the range.
260 Laser beam interrupted Repeat the
measurement.
Range
0.1 m to 30 m
0.33 ft to 100 ft
Measuring accuracy (2
σ
)
Typ.: ± 3.0 mm*
± 0.12 in*
Smallest unit displayed
1 mm (1/16 in)
Laser class
2
Laser type
635 nm, < 1 mW
Automatic switch-off
after 180 s
Continuous measuring
yes
Addition/Subtraction
yes
Area
yes
Volume
yes
Pythagoras
yes
Unit switching
yes
Dimension (H x D x W)
118 x 50 x 26 mm
4.65 x 1.97 x 1.02 in
Battery durability
(2 x AAA)
up to 3000
measurements
Weight
100 g
3.22 ounce
Temperature range:
- Storage
- Operation
-25°C to +70°C
(-13°F to +158°F)
0°C to +40°C
(32°F to +104°F)
Warning
Possible disturbance of other devices
(e.g. safety equipment, medical equipment)
due to electromagnetic radiation!
Â
Observe the safety instructions of the respective
devices.