Fluke 323 PLUS User Manual Download Page 13

 Clamp 

Meter 

 

How to Clean the Product 

Note 

The Measurement Category (CAT) and voltage rating of combinations of test 
probes, test probe accessories, current clamp accessories, and the Product is the 
LOWEST rating of individual components. 

How to Clean the Product 

Regularly wipe the case with a damp cloth and weak detergent. 

W

 

Caution 

To prevent damage to the Product, do not use abrasives or solvents to clean 
the Product case. 

To clean the Product jaw: 
1. 

Examine the jaw mating surface to make sure it is clean. If there is unwanted material 
(including rust), jaw closure will not be correct and there will be measurement errors. 

2. 

Open the jaws and clean the clamp metal ends with a lightly oiled cloth. 

 

Summary of Contents for 323 PLUS

Page 1: ...ber 2015 2015 Fluke Corporation All rights reserved Specifications are subject to change without notice All product names are trademarks of their respective companies 323 324 PLUS Clamp Meter Users Ma...

Page 2: ...e center to obtain return authorization information then send the product to that Service Center with a description of the problem THIS WARRANTY IS YOUR ONLY REMEDY NO OTHER WARRANTIES SUCH AS FITNESS...

Page 3: ...i Table of Contents Title Page Introduction 1 How to Contact Fluke 1 Safety Information 2 Symbols 7 How to Clean the Product 9 Specifications 10 The Meter 15...

Page 4: ...323 324 PLUS Users Manual ii...

Page 5: ...n in all of the illustrations For temperature measurement you must use the included K Type Thermocouple XWWarning Read Safety Information before you use the Product How to Contact Fluke To contact Flu...

Page 6: ...om To see print or download the latest manual supplement visit http us fluke com usen support manuals Safety Information A Warning identifies conditions and procedures that are dangerous to the user A...

Page 7: ...not touch voltages 30 V ac rms 42 V ac peak or 60 V dc Carefully read all instructions Hold the Product behind the tactile barrier See Clamp Meter item Do not exceed the Measurement Category CAT ratin...

Page 8: ...live conductors are exposed Replace the batteries when the low battery indicator shows to prevent incorrect measurements The battery door must be closed and locked before you operate the Product Meas...

Page 9: ...tes incorrectly Do not use test leads if they are damaged Examine the test leads for damaged insulation exposed metal Check test lead continuity Before each use examine the Product Look for cracks or...

Page 10: ...surement is necessary to know if a circuit is hazardous Do not use in CAT III or CAT IV environments without the protective cap if included with the Product installed on test probe The protective cap...

Page 11: ...tives W WARNING RISK OF DANGER Battery Consult user documentation T Double insulated X WARNING HAZARDOUS VOLTAGE Risk of electric shock Certified by CSA Group to North American safety standards Confor...

Page 12: ...ation MEASUREMENT CATEGORY IV is applicable to test and measuring circuits connected at the source of the building s low voltage MAINS installation Conforms to relevant South Korean EMC Standards This...

Page 13: ...the Product Regularly wipe the case with a damp cloth and weak detergent W Caution To prevent damage to the Product do not use abrasives or solvents to clean the Product case To clean the Product jaw...

Page 14: ...00 400 0 A Batteries 2 AAA NEDA 24A IEC LR03 Operating Temperature 10 C to 50 C Storage Temperature 30 C to 60 C Operating Humidity Non Condensing 10 C 90 RH at 10 C to 30 C 75 RH at 30 C to 40 C 45...

Page 15: ...y generated and or uses conductively coupled radio frequency energy that is necessary for the internal function of the equipment itself Class A Equipment is suitable for use in all establishments othe...

Page 16: ...ce of it This equipment is intended for use in business environments and not to be used in homes USA FCC 47 CFR 15 subpart B This product is considered an exempt device per clause 15 103 Temperature C...

Page 17: ...esolution 0 01 0 1 A Accuracy 2 0 5 digits AC Voltage Range 600 0 V Resolution 0 1 V Accuracy 45 Hz 400 Hz 1 5 5 digits DC Voltage Range 600 0 V Resolution 0 1 V Accuracy 1 5 digits Resistance Range 3...

Page 18: ...S 30 Capacitance 324 PLUS Range 100 0 1000 F Resolution 0 1 1 F Accuracy 1 4 digits Contact Temperature 324 PLUS Range 10 0 C to 400 0 C Resolution 0 1 C Accuracy 1 8 digits Note Temperature uncertain...

Page 19: ...Clamp Meter The Meter 15 The Meter 1 2 300 V CAT 600 V CAT 300 V CAT 600 V CAT TRUE RMS CLAMP METER gtq008 eps...

Page 20: ...323 324 PLUS Users Manual 16 20 OFF ON ON 323 324 PLUS gtq001 eps...

Page 21: ...Clamp Meter The Meter 17 ON 2 00 2 00 gtq002 eps...

Page 22: ...323 324 PLUS Users Manual 18 300 V CAT 600 V CAT 300 V CAT 600 V CAT TRUE RMS CLAMP METER 300 V CAT 600 V CAT 300 V CAT 600 V CAT TRUE RMS CLAMP METER 324 PLUS 323 gtq003 eps...

Page 23: ...Clamp Meter The Meter 19 300 V CAT V V or 30 V V 323 V dc 324 PLUS V dc V ac V 323 V ac gtq004 eps...

Page 24: ...323 324 PLUS Users Manual 20 300 V CAT 600 V CAT 300 V CAT 600 V CAT TRUE RMS CLAMP METER 300 V CAT 600 V CAT 300 V CAT 600 V CAT TRUE RMS CLAMP METER 70 323 324 PLUS 30 gtq005 eps...

Page 25: ...Clamp Meter The Meter 21 HOLD 20 V 30 V 300 V CAT 600 V CAT TRUE RMS CLAMP METER AC DC ZERO AC DC ZERO AC DC ZERO AC DC ZERO 2 sec gtq006 eps...

Page 26: ...323 324 PLUS Users Manual 22 300 V CAT 600 V CAT TRUE RMS CLAMP METER gtq009 eps...

Page 27: ...Clamp Meter The Meter 23 AAA gtq007 eps...

Page 28: ...323 324 PLUS Users Manual 24...

Reviews: