Specifications 

Electrical Characteristics 

Measurement Range 

20 to 1000 A (with a crest factor 

3) 

Frequency Range 

40 Hz to 5 kHz 

Accuracy (@ 25 °C) 

±1 % of reading 

Linearity (10 % to 100 % of range) 

±0.2 % of reading 

Temperature Coefficient 

±0.05 % of reading per °C 

Position Sensitivity (with cable >25 
mm from the coupling) 

 
±2 % of reading 

External Field (with cable >200 mm 
from the head) 

 
±1 % of reading 

Working Voltage (see Safety 
Standards) 

 
1000 V ac rms or dc 

General Characteristics 

Probe Cable Length 

24 in. (610 mm)   

Probe Cable Diameter 

0.3 in. (8 mm) 

Transducer Bend Radius (min) 

1.5 in. (38.1 mm) 

Output Cable 

2 core screened, double insulated, 3 
meters long 

Output Connector 

LEMO 6 pin male connector  

Operating Temperature Range 

-4 to +158 

°

F (-20 to +70 

°

C) (the 

temperature of the conductor under test 
shall not exceed 176 

°

F /80 

°

C) 

Storage Temperature Range 

-40 to 176 

°

F (-40 to +80 

°

C) 

Operating Humidity 

15 % to 85 % (non condensing) 

Altitude 

max 6562 ft. (2000 m) 

Degree of ingress protection 

IP40 (IEC 60529) 

Safety Standards 

IEC 61010-1: Pollution Degree 2 / IEC 61010-2-032: 1000 V CAT III 
Use of the Probe on uninsulated conductors is limited to 1000 V under CAT III 
installations and 600 V under CAT IV installations ac rms or dc and frequencies 
below 1 kHz. Note that the safety rating for the output to ground is limited to 30 V ac 
rms or dc by the connector specified. 

LIMITED WARRANTY AND LIMITATION OF LIABILITY 

This Fluke product will be free from defects in material and workmanship for one 
year from the date of purchase. This warranty does not cover fuses, disposable 
batteries, or damage from accident, neglect, misuse, alteration, contamination, or 
abnormal conditions of operation or handling. Resellers are not authorized to extend 
any other warranty on Fluke’s behalf. To obtain service during the warranty period, 
contact your nearest Fluke authorized service center to obtain return authorization 
information, then send the product to that Service Center with a description of the 
problem. 
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH 
AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. 
FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR 
CONSEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR 
THEORY. Since some states or countries do not allow the exclusion or limitation of 
an implied warranty or of incidental or consequential damages, this limitation of 
liability may not apply to you. 

Fluke Corporation 
P.O. Box 9090 
Everett, WA  98206-9090 
U.S.A. 

Fluke Europe B.V. 
P.O. Box 1186 
5602 BD Eindhoven 
The Netherlands 

11/99 