Fluke 1620A DEWK Getting Started Download Page 7

1 Before You Start

Symbol

Description

The European Waste Electrical and Electronic Equipment (WEEE) Directive (2002/96/

EC)  mark.

Safety Information

Use this instrument only as specified in this manual. Otherwise, the protection provided by the 

instrument may be impaired.

The following definitions apply to the terms “WARNING” and “CAUTION”.

“WARNING” identifies conditions and actions that may pose hazards to the user.

“CAUTION” identifies conditions and actions that may damage the instrument being used.

WARNINGS

To avoid personal injury, follow these guidelines.

DO NOT 

use this unit in environments other than those listed in the User’s Guide.

Follow all safety guidelines listed in the User’s Guide.
Calibration equipment should only be used by trained personnel.
The AC adapter can present safety concerns if misused or damaged. To avoid the risk 

of electric shock or fire, do not use the AC adapter outdoors or in a dusty, dirty, or wet 

environment. If the cord, case, or plug of the adapter is damaged in any way, discontinue 

its use immediately and have it replaced.
Never disassemble the AC adapter. Use only the AC adapter provided with the instrument 

or equivalent adapter recommended by the manufacturer of this instrument.
The AC adapter has circuits with high voltage inside that could present danger of 

electrical shock or fire if exposed. If the AC adapter is damaged in any way or becomes 

hot, discontinue its use immediately, disconnect it from any AC supply, and have it 

replaced. Do not attempt to open, repair, or continue using a damaged or defective AC 

adapter.
The instrument battery can present danger if not handled properly. To avoid the risk of 

exposure to dangerous substances or explosion, immediately remove the battery and 

discontinue use if it leaks or becomes damaged. Never allow the battery to be shorted, 

heated, punctured, or dropped. If the instrument is physically damaged, immediately 

remove the battery to insure that it does not become shorted. While removed from the 

instrument, store the battery in a location so that it will not come into contact with 

metal or fluids that might short circuit the battery and where it is safe from excessive 

temperatures.
Used batteries must be disposed of properly. Check your local regulations for additional 

information. Never dispose of batteries in fire which may result in explosion with the 

possibility of personal injury or property damage.

Summary of Contents for 1620A DEWK

Page 1: ...Revision 671901 1620A DewK Thermo Hygrometer Getting Started Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Page 2: ...purchase price free of charge repair or replacement of a defective product which is returned to a Hart authorized service center within the warranty period To obtain warranty service contact your nea...

Page 3: ...tal Conditions 8 Quick Start 9 Unpacking 9 Use Proper Care 9 Learn About the Features and Components 9 Install the Battery 9 Connect the Sensor 10 Connect the Power Source 10 Switch the Power On 10 Me...

Page 4: ...ery 17 Sensor Configuration 18 Power Switch 18 Power On Self Test 18 Display Contrast 18 Display 18 Alarm Screen 18 Measuring 19 Unit of Temperature 19 Recording Measurements 19 Sensors 19 Sensor Accu...

Page 5: ...cess to settings Ethernet LAN interface provides TCP IP communicatins and embedded HTML web page for reading measurements over a network Optional wireless RF 802 15 4 ZigBee for remote operation Visua...

Page 6: ...Guide Important Information Off On Canadian Standards Association OVERVOLTAGE Installation CATEGORY II Pollution Degree 2 per IEC1010 1 refers to the level of Impulse Withstand Voltage protection pro...

Page 7: ...the AC adapter provided with the instrument or equivalent adapter recommended by the manufacturer of this instrument The AC adapter has circuits with high voltage inside that could present danger of...

Page 8: ...t be visibly apparent but can cause drift instability and loss of accuracy Observe the following precautions DO NOT allow sensors to be dropped struck or stressed DO NOT overheat sensors beyond their...

Page 9: ...EAN Regional Office Service Center 60 Alexandra Terrace 03 16 The Comtech Lobby D 118502 SINGAPORE Phone 65 6799 5588 Telefax 65 6799 5588 E mail antng singa fluke com When contacting these Service Ce...

Page 10: ......

Page 11: ...up to 0 01 0 1 recorded Inputs Two sensors each measuring temperature and relative humidity each is detachable cable extendable and interchangeable with self contained calibration each may be assigne...

Page 12: ...he User s Guide For full accuracy operate the instrument within the calibrated temperature and relative humid ity range of the sensors 1620A DewK Operating Temperature 0 C to 50 C 32 F to 122 F Relati...

Page 13: ...ginning of this guide The thermo hygrometer and sensors used with it are sensitive instruments that can be easily damaged Always handle these devices with care DO NOT allow them to be dropped struck s...

Page 14: ...r switch to the position The instrument takes a few seconds to power up initialize and begin normal operation A self test is performed displaying the channel configuration and status of the system cal...

Page 15: ...functions of each of the buttons from the main screen are as follows ENTER MENU This button is used to display the menu options EXIT This button is used to display the alarm window With the alarm win...

Page 16: ...ion cable may be used to allow the sensor to be placed in a remote location Figure 2 Top Panel Right Side Panel The right side panel contains the port for attaching the sensor for Channel 2 An optiona...

Page 17: ...d the tip is positive DC Power Socket The DC plug from the AC adapter plugs into the 12V DC power socket to power the instrument The jack accepts a 5 5 mm miniature power plug Switchcraft S760 The out...

Page 18: ...ns When the main screen is displayed the buttons have the following functions ENTER MENU This button is used to display the menu options EXIT This button is used to display the alarm window With the a...

Page 19: ...case 2607 sensor wall mount bracket 2630 and 25 foot 7 6 m extension cable 2628 2607 Spare Sensor Protective Case 2628 Extension cable 7 6 m 25 ft 2629 Extension cable 15 2 m 50 ft 2630 Sensor wall mo...

Page 20: ......

Page 21: ...continuous measurement and recording during power outages The recommended battery type is a standard 9 V alkaline battery NEDA 1604A or IEC 6LR61 During a power outage or when the ac adapter is disco...

Page 22: ...Self Test When power is turned on the thermo hygrometer performs a self test checking the system sensors sensor calibration parameters memory and buttons If an error occurs an error mes sage is displ...

Page 23: ...d is also set with this function Sensors The standard accuracy sensor and high accuracy sensor are used to measure temperature and relative humidity The sensors attach to the thermo hygrometer by plug...

Page 24: ...lf heating does depend somewhat on the velocity of the air around the sensor The sensor is calibrated in nearly still air Different air velocities can cause differences in the measured temperature of...

Page 25: ...21 5 General Operation...

Page 26: ......

Reviews: