background image

 

FW_F112A_v1702_02_EN

 

Page 28 

Terminal 12-13: Type IB 

– external reset: 

With this function the total can be reset to zero with an external switch. The Total resets only when 
the switch 

opens

. When a Normally Closed (NC) contact is used, the local clear total function is 

disabled and a clear total is only possible with the external reset command. 
The input must be switched with a potential free contact to the terminal 12. 

 

 

Fig. 19: Terminal connections - External reset (typical) 

Terminal 26-31: type CB / CH / CI / CT - communication RS232 / RS485 / TTL (option): 

For connections, refer to figure: Overview of terminal connectors - Standard configuration and options 

Full serial communications and computer control in accordance with RS232 (length of cable max. 15 
meters) or RS485 (length of cable max. 1200 meters) is possible. 
When using the RS232 communication option, terminal 27 is used for supplying the interface. 
Please connect the DTR (or the RTS) signal of the interface to this terminal and set it active (+12V). 
If no active signal is available it is possible to connect a separate supply between terminals 
26 and 27 with a voltage between 8V and 24V. 
 

Terminal 00 - 01: type ZB backlight (option): 

If the unit is supplied with a power supply: 

  type PD, PF or PM, the backlight supply is integrated. 

  type PX, use the terminals 00 and 01 to supply the backlight. 

The backlight intensity is set in the setup menu: Display. 
 

 

Summary of Contents for F112-A

Page 1: ...al input flowmeter 0 4 20mA Signal outputs 4 20mA ref flowrate and pulse ref total Options Intrinsically safe Modbus communication external reset and backlight F Series Field mounted indicators for sa...

Page 2: ...the general waste system or into a landfill At the end of its life equipment shall be disposed of according to the local regulations regarding waste of the electrical and the electronic equipment Plea...

Page 3: ...A or connected instruments A caution indicates actions or procedures which if not performed correctly may lead to personal injury or incorrect functioning of the F112 A or connected instruments A not...

Page 4: ...n 16 3 1 11 Explanation of SETUP menu A Others 16 4 Installation 17 4 1 General directions 17 4 2 Installation surrounding conditions 17 4 3 Dimensions Enclosure 18 4 4 Installing the hardware 20 4 4...

Page 5: ...mA or 0 10V signal limits can be tuned Fig 1 Typical application Configuration The F112 A is designed for use in many types of applications For that reason a setup menu is available to program the F11...

Page 6: ...s operators 2 1 CONTROL PANEL The control panel has three keys The available keys are Fig 2 Control Panel Functions of the keys This key is used to program and save new values or settings The PROG ENT...

Page 7: ...key is pressed once the text PUSH CLEAR is shown To avoid a reset at this stage press another key other than the CLEAR key or wait for 20 seconds A reset of the total does not influence the accumulate...

Page 8: ...le to prevent access to the SETUP menu with a password A password may be required to enter the SETUP menu Without this password access to SETUP is denied 3 1 HOW TO PROGRAM THE F112 A The setup menu h...

Page 9: ...d the setting UNIT When you do not want to save the change wait for approximately 20 seconds or press and hold the PROG ENTER key for approximately 3 seconds Action Result Remark 1 Momentarily press t...

Page 10: ...er 01 99 53 cut off 0 0 99 9 54 calib lo default calibrate calibrate set 55 calib hi default calibrate calibrate set 6 LINEARIZATION 61 M FACTOR 1 0 01 99 99 0 9 999999 62 M FACTOR 2 0 01 99 99 0 9 99...

Page 11: ...r for the span 041355 and for the span decimals 6 When you recalculate and enter a new span the history for accumulated total is not correct anymore because the accumulated total is not recalculated f...

Page 12: ...xample battery life time with a coil pick up FAST update about 2 years 1 sec update about 5 years BATTERY MODE 42 The F112 A has two modes operational or shelf After shelf has been selected the F112 A...

Page 13: ...e the real output value at maximum flow rate Be very sure that the offered signal is correct before the calibration is executed as this function has major influences on the accuracy of the system Afte...

Page 14: ...ower consumption e g save battery life time Option AP When a power supply is available but the output is disabled a 3 5mA signal will be generated RATE MIN 72 Enter here the flow rate at which the out...

Page 15: ...w rate can be obtained The filter principal is based on three input values the filter level 01 99 the last calculated flow rate and the last average value The higher the filter level the longer the re...

Page 16: ...setting 9600HP is a high power setting Modbus compliant ADDRESS 92 This setting is used to set the communication address for the F112 A MODE 93 This setting is used to set the Modbus transmission mode...

Page 17: ...en the housing cover is removed or the panel cabinet has been opened danger from electrical shock The housing may only be opened by trained persons authorized by the operator of the facility Take care...

Page 18: ...mm 30mm M20 x 1 5 M16 x 1 5 M16 x 1 5 30mm 30mm M20 x 1 5 M20 x 1 5 M20 x 1 5 25mm 25mm 1 2 NPT 0 9 3x 1 2 NPT 0 12 0 12 HA HM HN HO HP HT HU 6 x M12 12mm 12mm 24mm 24mm 36mm 36mm 14mm 17mm 115 mm 4 5...

Page 19: ...120 mm 4 72 HD HK HK back box flat bottom HE HF HG HH D 12mm 12mm 12mm 24mm 24mm 36mm 36mm 14mm 17mm 22 5mm 30mm 30mm D 16mm D 20mm 0 9 D 22mm 0 866 22 5mm 25mm 25mm D 20mm D 20mm D 16mm HC 75 mm 2 9...

Page 20: ...hat came with a power module type PM 110V 230V AC or type PD PF with an option OR the relays can handle 110V 230V AC shall be connected to the Protective Earth PE stud which is installed in the metal...

Page 21: ...screws that attach the cover to the back panel Type PM 110 230V AC The PE connection in the metal back panel is made with a serrated washer a terminal a washer and a screw The PE connection to the me...

Page 22: ...C GRP ENCLOSURE The PE connection The F112 P in a GRP enclosure meets the requirements of class 2 double insulated Therefore the incoming PE wire is terminated with an insulating end cap Type PM 110 2...

Page 23: ...influence the battery life time It is strongly advised to use a zero power pickup such as a coil or reed switch when operating without external power It is possible to use some low power NPN or PNP ou...

Page 24: ...4V DC 18Vin AC 26Vin DC Type PF Power supply in 15 24V AC 20 30V DC Switch location typical Sensor Vout selection Sensor supply out A 1 2 3 4 int off off Coil 1 2V DC 1mA Reed 3V DC 1mA ext on on off...

Page 25: ...type AP output loop powered Connect an external power supply of 8 30VDC to these terminals or a 0 4 20mA loop Do connect the to terminal 7 and the to terminal 8 When power is applied to these terminal...

Page 26: ...is option When the output is disabled a 3 5mA signal will be generated on these terminals Max driving capacity 1000 Ohm 30VDC This option can be used with a battery powered unit but the life time of t...

Page 27: ...16 bits accuracy The input is not isolated For Intrinsically safe applications without input loop power please read chapter 5 Fig 17 Terminal connections Analog signal input typical Terminal 09 10 Typ...

Page 28: ...al connectors Standard configuration and options Full serial communications and computer control in accordance with RS232 length of cable max 15 meters or RS485 length of cable max 1200 meters is poss...

Page 29: ...IP65 in accordance with IEC 60529 suitable cable entries and blanking elements must be used and correctly installed For enclosures and windows with a high surface resistance potential charging hazard...

Page 30: ...of production This information can be looked up in the setup menu Others Fig 20 Example serial number typical Label information pulse input type F1xx XI inside and outside the enclosure Fig 21 Label...

Page 31: ...ly connected to terminals 7 and 8 type AP The maximum values for any of those circuits are those as defined for group IIB IIIC No other active external Intrinsically safe circuits may be connected to...

Page 32: ...nal power is only available when the main external power supply is connected The sensor supply voltage is fixed 8 2V DC Set the sensor supply 1 Make the F112 P safe If applicable mind the battery powe...

Page 33: ...FW_F112A_v1702_02_EN Page 33 5 3 CONFIGURATION EXAMPLES INTRINSICALLY SAFE APPLICATIONS Fig 25 F112 A AF CT IB OT PC PD XI Battery powered IIB IIC IIIC...

Page 34: ...FW_F112A_v1702_02_EN Page 34 Fig 26 F112 A AF CT IB OT PD XI External power supply IIB IIC IIIC...

Page 35: ...with the utmost care to prevent a short circuit and damage 4 Do not recharge crush disassemble incinerate heat above its rated temperature or expose the contents to water 5 Dispose of the battery in a...

Page 36: ...utput signal be sure that an external power supply is connected or that the function is disabled if not in use or else it will have a major influence on the battery life time Display update fast displ...

Page 37: ...TYPE 4 X Drilling 2x PG9 1x M20 Drilling 2x M16 1x M20 Drilling 1x M20 Drilling 2x M20 Drilling 6x M12 Drilling 1x NPT Drilling 3x NPT No drilling No drilling Drilling 2x 16mm 0 63 1x 20mm 0 78 Drill...

Page 38: ...MC EN 61326 1 FCC 47 CFR part 15 LVD EN IEC 61010 1 ATEX IECEx EN IEC 60079 0 EN IEC 60079 11 RoHS EN 50581 IP NEMA EN 60529 NEMA 250 Flowmeter Type A 0 4 20mA with signal calibration feature at any c...

Page 39: ...ic relay output max switch power 230V AC 0 5A requires type PF or PM Type OT Passive transistor output not isolated Load max 50V DC 300mA Type OR Electro mechanical relay output max switch power 230V...

Page 40: ...total is counting Check are the Span and time unit correct Linearization does not work Check is the function enabled are all M Factors and the frequency entered correctly The password is unknown If t...

Page 41: ...information regarding using your Modbus device please read our General Modbus Communication Protocol and Modbus troubleshooting guide that are available through our website or your distributor Runtim...

Page 42: ...RESS REGISTER VARIABLE POWER MANAGEMENT NO REGISTERS R W TYPE VALUE REMARKS d 80 h 0x050 40081 LCD update time 1 r w uint16 0 fast 1 1sec 2 3sec 3 15sec 4 30sec 5 off d 81 h 0x051 40082 power mode 1 r...

Page 43: ...F 40128 filter 1 r w uint16 1 99 PDU ADDRESS REGISTER VARIABLE PULSE NO REGISTERS R W TYPE VALUE REMARKS d 128 h 0x080 40129 pulse width 1 r w uint16 0 9999 Representation 0 001 9 999 sec d 133 h 0x08...

Page 44: ...FW_F112A_v1702_02_EN Page 44 APPENDIX D DECLARATION OF CONFORMITY...

Page 45: ...al connectors Standard configuration and options 23 Fig 8 Sensor supply voltage Switch setting 24 Fig 9 Terminal connections Active output typical 24 Fig 10 Terminal connections Mechanical relay outpu...

Page 46: ...lib lo default 55 calib hi default 6 LINEARIZATION 61 percentage 0 0 M Factor 1 000000 62 percentage 0 0 M Factor 1 000000 63 percentage 0 0 M Factor 1 000000 64 percentage 0 0 M Factor 1 000000 65 pe...

Page 47: ...max 99999 74 cut off 0 0 75 tune min 160 76 tune max 6656 77 filter 1 8 RELAY OUTPUT 81 width 0 000 82 decimals 0000000 83 amount 1000 9 COMMUNICATION 91 speed 9600 92 address 1 93 mode BUS RTU 94 da...

Page 48: ...Fluidwell B V PO box 6 Voltaweg 23 Website www fluidwell com 5460 AA Veghel 5466 AZ Veghel Find your nearest representative www fluidwell com representatives the Netherlands the Netherlands 2017 Fluid...

Reviews: