• The
DC IN
connection is a 5-pin M12A port, exclusively designed to
accept passive 48 Vdc power.
• The
LAN
connection is an 8-pin M12X port, designed to connect
the unit to a local area network (LAN) switch and/or to an IEEE
802.3 48 Vdc power source.
• The
SFP
connection is a small form-factor pluggable (SFP) port,
exclusively designed to connect the unit to a duplex fiber-optic data
link.
IMPORTANT
The Fluidmesh 4200 FIBER is shipped from the factory with no
fiber-optic transceiver installed. For the unit to have fiber-optic
capability, the SFP port must be equipped with a separate
fiber-optic transceiver.
4.1.4. Rebooting the firmware and resetting the unit to factory
defaults
The Fluidmesh 4200 FIBER hardware can be rebooted and reset to
factory default condition using the procedures in this section.
IMPORTANT
The following procedure shows how to do a 'hard' (device
firmware) reboot. To do a 'soft' (device software) reboot, refer
to
“Resetting the unit to factory defaults” (page 147)
.
To do a 'hard' (device firmware) reboot under emergency conditions (for
example, if the unit malfunctions), do the steps in the following sub-
section.
Device firmware reboot
1.
Remove the Phillips-head screw labelled
RESET
at the bottom of
the unit (
).
Figure 8. Fluidmesh 4200 FIBER (Hardware RESET protective
screw)