Assembling the Machines

 

 

Your Harbil NSC80 Compact Color Dispenser requires only the simple attaching of the individual canisters to 
the turntable or fastening to the in-line base. Do not fill the canisters with colorant before they are mounted on 
the base. 
 

For In-Line NSC80 Dispensers 

 

1.  Place the first canister in position on the in-line base or at the front of the turntable. 

 

2.  Screw three 1/4-20 hex-head bolts with rubber washers into the bottom of the canister and after all 

three bolts are in place snug them  up with a wrench (these bolts and washers are packaged in a 
separate bag with the red nozzle caps). DO NOT overtighten the bolts. 

 

3.  The canister covers can now be installed on the canisters. (See 

IMPORTANT

 note in turntable section, 

#3.) 

 

For Turntable NSC80 Dispensers 

 

1.  Place the first canister in position at the front of the turntable. 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2.  Depress the index lever and move the turntable to the next position and repeat the above 

procedure until all of the canisters are mounted. 
 

3.  The canister covers can now be installed on the canisters. 

 

IMPORTANT:

 

 

  The canister covers should be kept on the canisters at all times to minimize the 

evaporation and drying of the colorant. 

  Nozzle closers are provided with every canister to help prevent drying of the colorant 

and they closed after every use. 

 

Summary of Contents for Harbil NSC80

Page 1: ...Part No 37611 Rev A 07 15 Harbil NSC80 Compact Colorant Dispenser Operating and Instruction Manual...

Page 2: ...ral and state laws Fluid Management FMDirect ColorPro DVX Harbil Blendorama Accutinter Duraflow Fast Fluid Management GyroFlex GyroMixer MicroTint TintMaster V1 and VR1 are trademarks of Fluid Managem...

Page 3: ...nty does not cover software which is covered by separate warranty DISCLAIMER THIS WARRANTY SHALL BE APPLICABLE ONLY IF THE EQUIPMENT SHALL BE THE PROPERTY OF THE ORIGINAL PURCHASER OR USER AND SHALL H...

Page 4: ...pliance Information 7 FCC Compliance Statement Getting to Know Your NSC80 Dispenser 7 Technical Specifications 7 Environmental Conditions 7 Highlights 7 Features Getting Started 9 Unpacking Installati...

Page 5: ...es of this NSC80 Dispenser If you have internet access the most current information for your NSC80 Dispenser is available from the worldwide web at http www fluidman com For Your Safety Customer safet...

Page 6: ...lls you about a hazard that could cause serious injury to you or extensive damage to the equipment This information is featured in the beginning of the guide to emphasize safety When you see a Warning...

Page 7: ...nces Danger Improper installation of the grounding plug can result in a risk of electric shock If repair or replacement of the cord or plug is necessary DO NOT connect the grounding wire to either fla...

Page 8: ...ts Accurate dispensing through saw toothed self zeroing gauges 2 5 qt stainless steel canisters 2 oz piston pumps with 1 128 th minimum dispense accuracy colorant dependent Industrial grade seals and...

Page 9: ...e design the NSC80 Dispenser is an attractive unit and will always look like new with proper housekeeping Cleanliness of the dispenser and proper maintenance of the colorant in the machine are the onl...

Page 10: ...them up with a wrench these bolts and washers are packaged in a separate bag with the red nozzle caps DO NOT overtighten the bolts 3 The canister covers can now be installed on the canisters See IMPOR...

Page 11: ...to canisters 4 Shake of stir the colorant following manufacturer s recommendations 5 Slowly pour the colorant into the canister to the level of approximately two 2 quarts 6 Place the top on the canist...

Page 12: ...ulling the valve lever forward until a positive stop is felt 10 Open the nozzle closer by pressing the black lever to the right 11 Turn the gauge to the center of the indicator and slowly push the pum...

Page 13: ...ot be depressed DO NOT FORCE the pump gauge Release close the valve lever and then depress the pump gauge returning the colorant to the canister The failure to depress the pump gauge will be due to dr...

Page 14: ...the dispense stroke each time 1 Loosen black dial and slide repeatability gauge to desired location as specified in the formula 2 Dispense as directed on page 12 using the repeatability gauge as a st...

Page 15: ...ozzles outside cabinet surfaces with soap and water Check canisters and fill as required WEEKLY Cleaning Nozzle Maintenance Dispense a full measure of any colorant that has not been used during the pr...

Page 16: ...th the Thiokol Repair Kit P N 4231011 Cleaning the Canister Pump Assembly When it becomes necessary to clean a canister pump assembly remove the canister from the base and pour out as much of the colo...

Page 17: ...any power source before you attempt the replacement Fluid Management Customer Service 1 800 462 2466 Save time and money If something should go wrong we suggest consulting the Maintenance and Service...

Page 18: ...Fluid Management Customer Service 1 800 462 2466 12 Harbil NSC80 Series...

Page 19: ......

Page 20: ...NSC80Compact Colorant Dispenser Fluid Management Inc 1023 Wheeling Road Wheeling IL 60090 p 847 462 2466 f 847 537 3221 www fluidman com...

Reviews: