Troubleshooting your sprayer
PROBLEM
SOLUTION
POSSIBLE REASON
Does not turn on
1. Remove battery & reattach to sprayer
2. Charge battery
3. Disconnect & reconnect all 5 electrical
connections coming out of the pump
1. Battery is not fully connected
2. Battery is not charged
3. Electrical issue with pump
Leaking from tank area
Remove screws and remove the plastic
covering to expose pump. Loosen clamps
on both hoses, position hose closer to
pump and retighten hose clamp
Input and / or output hose(s) have a
loose connection with pump
Leaks from gun and / or nozzle area
1. Inspect all seals & replace if necessary
2. Contact FlowZone® at +1 803-339-2500
for replacement part
1. Loose / damaged / broken seal(s)
2. Ball valve inside gun assembly is
defective
Clogged pump / hose / gun / wand / nozzle
1. Rinse sprayer thoroughly with warm,
soapy water after each use
2. Run gasoline through the sprayer to
break up clogs
Not rinsing tank / pump / hose / gun /
nozzle(s) with cleaning solution or water
after each use
Random part breaks
Contact FlowZone® at +1 803-339-2500 for
replacement parts (see next page)
Wear and tear
07