Symptom

Mode lights on control panel do
not light when “MODE” switch is
d e p r e s s e d .

Probable Cause

No power at outlet

Unit not properly connected to its power pack.

Remedy

Check for electrical power at outlet.

Check plug connections between unit and power pack low voltage cord.

Green lights on control panel
are fla s h i n g .

Lack of propane.

Propane tank valve closed.

Regulator coupling not properly attached.

R e fill propane tank.

Open tank valve.

Check propane regulator coupling for proper engagement and/or leaks.

The fan does not run
continuously after the unit has
been on for at least 10 minutes.

Lack of propane

Start cycle malfunction.

Same as for “green lights fla s h i n g ” .

Press 

“ R e s e t ”

and restart in 24/7 mode.

Not catching mosquitoes when
the fan is running, the valve is
pulsing and the green lights on
the control panel are not
flashing.

Funnel end is not over catch tray
nozzle opening.

Funnel clogged with insect debris.

Trap is not located in a productive site.

Windy, cool or stormy weather.

Current  mosquito population not readily
attracted to CO

2

+ Octenol.

Engage the funnel end with the catch tray nozzle opening.

Clean funnel. See page 7.

Move trap to a new site. See placement guidelines in the owner’s manual.

Wait for conditions more to the mosquito’s liking.

Notably the day flying Asian tiger Mosquito. Operate the trap with the
octenol cartridge removed.

The unit does not start up at
dusk when in an automatic
mode.

Unit has not sensed dusk or night for a
full 10 minutes.

Ambient temperature is below
55-60ºF.

Ambient light level is too high.

Wait for 10 minutes of darkness.

Unit will start automatically if temperature rises above 55º F
within 2 hours of dusk.

Shield unit from extraneous  light.

Trouble Shooting Chart

Mosquito Attractant:
Octenol Cartridge – MA 1000

Makes your Mosquito PowerTr a p
more effective in attracting mosquitoes
and biting fli e s .

Extension Cord – EC-50

50 foot low voltage extension cord.
Allows placement of the Mosquito
P o w e r Trap an additional 50 feet away
from the power source.

Accessories

Accessories are available at your local retail outlet or on-line at www.flowtron.com

Any problems you encounter that are not corrected by the action recommended in this chart should be referred to the Flowtron Service Department • (800) 343-3280

WARRANTY

Flowtron warrants your Mosquito PowerTrap to be free from defects in materials or workmanship under normal use and service for one year from date of original purchase. All parts
which are defective will be replaced free of charge. Any implied warranties, including the implied warranty of merchantability are also limited in duration to the one year period from the
original purchase date.

The provisions of this warranty shall not apply to any product which as been subject to misuse, neglect or accident, nor which is used for a purpose for which it is not designed, or
which shall have been repaired or altered in any way so as to adversely affect its performance and reliability. Service by unauthorized parties voids your warranty. Warranty covers
only the original purchaser. Commercial and/or professional use is excluded from warranty coverage.

Flowtron neither assumes nor authorizes any person to assume for it any other liability in connection with its product. No responsibility is assumed for any consequential damages
that may result from the use of a Flowtron product, nor for damages due to accident, abuse, lack of responsible care, the affixing of any unauthorized attachment, loss of parts or
subjecting this unit to any but the specified voltage.

If the unit fails to operate during the warranty period, send the product, along with purchase receipt showing purchase date and description of the problem to: Flowtron Service
C e n t e r, 15 Highland Avenue, Malden, MA 02148. Transportation costs for returning any defective product are the responsibility of the consumer.

This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

Flowtron Outdoor Products, 15 Highland Ave, Malden, MA 02148 

1 - 8 0 0 - 3 4 3 - 3 2 8 0

557-10051

Summary of Contents for Mosquito PowerTrap MT-200 Series

Page 1: ...OPERATING INSTRUCTIONS BEFORE USING Please retain operating instructions for future reference DOMESTIC REG NO 28457 PCPA Flowtron Mosquito PowerTrap Operating Instructions Flowtron Outdoor Products 15 Highland Ave Malden MA 02148 1 800 343 3280 www flowtron com ...

Page 2: ...k Support Strap 1 Tank Stand Assembly 1 TankWrap 1 Tank Cap 1 Tank Strap 1 Owners Manual Mosquito PowerTrap Tank Stand Assembly Wheels MT 300 series only Tank Cap Tank Wrap Tank Strap Octenol Cartridge and Owner s Manual are not shown Post Power Pack and Low Voltage Wire Catch Tray Unpacking Instructions Your Mosquito PowerTrap has been carefully packed at the factory to prevent damage during ship...

Page 3: ...et to 125 feet 30 40 m At close range body heat moisture and lactic acid serve as terminal attractants Certain species show strong preferences for biting different parts of the human body This is thought to be related to local skin temperature and lactic acid output The attractiveness of different persons to mosquitoes varies substantially Men are bitten more readily than women adults more often t...

Page 4: ...itical for successful results Your Flowrtron Mosquito PowerTrap emits a plume of octenol enhanced carbon dioxide which mosquitoes follow in their search for a blood meal Mosquitoes fly up wind toward the source of the plume in their attempt to locate a host Since the direction of the plume is dependent upon the direction of the wind your unit should be positioned so it s attractant outlet faces do...

Page 5: ...0 series 1 Insert one end of the post into the post opening at the front of the tank stand Insert opposite end of post into the post opening located at the bottom of the Flowtron Mosquito PowerTrap Align unit in relation to the tank stand See Illustration 2 Place a 20 lb tank on the tank stand and install tank wrap around the tank 2 Install catch tray by first inserting the rear of the tray into t...

Page 6: ...ºF 13º 15ºC This is an important feature to conserve propane fuel The unit will automatically begin its start cycle when the light level reaches dusk and remains at the level of dusk for ten minutes thus avoiding the effects of transient light sources and if the outside air temperature is above the 55º 60ºF 13º 15ºC range The start cycle is also repeated at dawn when the 3 2 hr or the 4 3 hr mode ...

Page 7: ...de of unit s hous ing See figure C Push funnel upwards and with the rear section of the bottom funnel ring at a slight angle compress funnel until front tabs of bottom funnel ring are up inside of the housing See figure D Release funnel and it will spring into place Replace catch tray and re start unit Operating Mode Hours per Day Refill Times 20 lb propane tank Octenol Cartridge U S Government an...

Page 8: ...s placement of the Mosquito PowerTrap an additional 50 feet away from the power source Accessories Accessories are available at your local retail outlet or on line at www flowtron com Any problems you encounter that are not corrected by the action recommended in this chart should be referred to the Flowtron Service Department 800 343 3280 WARRANTY Flowtron warrants your Mosquito PowerTrap to be fr...

Reviews: