![Flowtron Mosquito PowerTrap MT-125 Technical Manual Download Page 16](http://html.mh-extra.com/html/flowtron/mosquito-powertrap-mt-125/mosquito-powertrap-mt-125_technical-manual_2308621016.webp)
D.
PowerTrap Start-Up Characteristics (Temperature
—
Fahrenheit)
Function
Elapsed Time
Temperature
Comments
Srart
0:00
78 F Ambient
Valve Pulses
1 -2:10
190 -
F
Valve makes clicking sound;Gas flow
starts
Fan Starts
2:30 - 3:00 min.
345 - 355 F
"On" 1 second every 20 - 30 seconds
Fan Intermittent
445
—
455 F
"On" 2 second every 20 - 30 seconds
Fan Intermittent
545 - 555 F
"On" 3 second every 20 - 30 seconds
Fan Intermittent
645 - 655 F
"On" 4 second every 20 - 30 seconds
Fan Continuous
5:00
—
8:00 min.
755 - 765 F
Auto control begins
Start-up Complete
10:00
—
12:00 min
1040 - 1100 F
Stablizes at normal operating temperature
PowerTrap Start-Up Characteristics
(Temperature
—
Celsius)
Fan Continuous
5:00
—
8:00 min.
398
—
405 C
Auto control begins
Start-up Complete
10:00
—
12:00
min
560 - 593 c
Stabilizes at normal operating temperature