- DO NOT run pumps continuously for longer then 30 minutes under a no flow (dead headed) situation.
- DO NOT over tighten plastic threaded connections. Breakage can occur, resulting in fluid exposure.
- If valve on end of hose is equipped with an internal check valve that does not allow air removal the pump
may need to be primed first in order to build up enough pressure to expel air in the system. The length of
hose, fluid level of tank and additional accessories will affect pump priming. It may be necessary to first fill
pump with water or chemical before connection of the hose.
- Teflon Tape is the recommended thread sealant on all pipe connections.
- Replace cartridge O-ring and Bottom Gasket if Pump Cartridge is removed or replaced.
- Flush pump assembly with water prior to any maintenance or new installation, as exposure to chemicals
can cause bodily harm. Gloves and proper eye protection should be worn.
Disassembly/ Assembly Procedures:
Pump Cartridge Removal:
1. Purge pump with clean water.
2. Disconnect Terminal Connection Clamps from 12-15 volt DC power source.
3. Remove Motor by removing the six (6) Screws from the pump assembly.
4. Remove Cartridge from Pump Housing by placing blunt object (Screw Driver Handle, etc.) into the suction
port of Pump Housing and push the Cartridge out of Pump Housing. Do Not pry cartridge from the Pump
Housing, as damage to O-ring area can occur.
Cartridge Installation:
1. Assure bottom Pump Housing Gasket is centered in bottom of Pump Housing.
2. Align flat surface on side of Pump Cartridge with discharge port on Pump Housing.
3. Push Pump Cartridge lightly on outside top surface into the Pump Housing. Do Not Force: if Cartridge does
not go down re-align Cartridge in Pump Housing.
4. Replace Motor Assembly onto Pump Housing with Cartridge in place. Be sure to align one of the six dim-
ples on the Wobble Plate with one of the 6 Motor Hold Down Screws. This will assure proper line up of Wob-
ble Plate on Piston tops.
5. Secure the six Screws into the Pump Housing using a diagonal tightening pattern. Recommended torque
specification is 28-32 in-lbs.
Motor Assembly Removal:
1. Purge pump with clean water.
2. Disconnect Terminal Connection Clamps from 12-15 volt DC power source.
3. Remove Motor by removing the six (6) Screws from the pump assembly.