![Flowserve FlowTop V726 Disassembly/Reassembly Instructions Download Page 17](http://html1.mh-extra.com/html/flowserve/flowtop-v726/flowtop-v726_disassembly-reassembly-instructions_2308391017.webp)
17
Schmidt Armaturen
AI - FlowTop
Mixing Valve
SPM - Code : V7xx
W
xVNA . . .
M
OTP2LG
Disassembly
Step 01
• Unscrew hexagon nuts (1.4)
Reassembly
Step 01
• Grease stud screws
CAUTION !
Lubrication as per Table 06
(Page 65)
• Screw hexagon nuts in place (1.4) and tighten in a
diagonally opposite sequence using the torque wrench
CAUTION !
Nut tightening moment (1.4)
as per Table 01
(Page 64)
When tightening the nuts pay attention to the
alignment of the plug (do not rub or insert the
plug in the open / closed movement)
• Tighten the hexagon nuts of the compression gland (3.6)
using the torque wrench
CAUTION !
Tightening moment of the hexagon nuts (3.6)
as per Variant drawing
(Page 61 - 63)