2.3  Position the P-200 cartridge gland with the gland gasket in place 

against the pump back plate (seal chamber/stuffing box) face, 

install flat washers on the studs to prevent misalignment, and 

tighten the gland nuts evenly, cross-staggering the adjustment  

of the nuts. Do not over tighten.

2.4  Assemble the pump, adjust the bearings, set the impeller  

and connect the coupling so that the shaft is in its operating  

axial position. Any subsequent axial adjustment of the shaft  

requires resetting of the seal. Connect pump piping,  

 

(see Section 3) allowing no pipe strain on the pump casing.

2.5  Tighten the set screws on the P-200 cartridge collar with the Allen 

wrench provided.

2.6  Remove setting devices by removing the cap screws with the 

Allen wrench provided. Save the setting devices for use if pump 

impeller must be reset or if the P-200 is removed for maintenance.

2.7  Turn the shaft by hand to ensure free operation.
2.8  Pipe up the gland connections to the P-200 seal as explained in 

Section 3.

2.9  See Operational Recommendations, Section 4, before starting 

pump.

3 Piping

3.1    Install an ANSI 7311 flush for horizontal pumps or ANSI 7313 

for vertical pumps. from the pump discharge to the P-200 seal 

flush port,  

a

  Figure 4. To maximize seal life, Flowserve recom-

mends a product bypass flush be used whenever possible with a 

P-200 seal installed in conventional stuffing box. A bypass flush is 

not necessary when an enlarged tapered or cylindrical seal cham-

ber is used. If a bypass flush is not used, plug the flush port  

a

 .

Summary of Contents for Durametallic P-200

Page 1: ...Installation Instructions Experience In Motion Cartridge dual pusher seal for standard and big bore ANSI pumps Durametallic P 200...

Page 2: ...sure in the system Consult plant MSDS files for hazardous material regulations Seal Chamber Requirements Figure 1 To first obstruction Shaft or sleeve OD 0 000 mm 0 000 inch 0 050 mm 0 002 inch 0 000...

Page 3: ...1 02 0 375 0 625 4 12 5 12 2 125 2 875 3 250 1 97 1 88 2 00 1 02 0 375 0 625 4 38 6 00 2 250 3 000 3 375 1 97 1 88 2 00 1 02 0 375 0 625 4 62 6 50 2 375 3 250 3 625 2 16 2 06 2 09 1 11 0 375 0 625 5...

Page 4: ...ight cause leakage at the gland gasket or misalign the seal gland 1 6 Check equipment dimensions to ensure they are within the dimensions shown in Figures 1 and 2 Critical dimensions include shaft or...

Page 5: ...ward the bearing housing 2 2 Install pump back plate seal chamber stuff ing box Figure 3 Position the P 200 seal gland flush connection port a in Figure 4 in the 3 o clock position for normal installa...

Page 6: ...h provided 2 6 Remove setting devices by removing the cap screws with the Allen wrench provided Save the setting devices for use if pump impeller must be reset or if the P 200 is removed for maintenan...

Page 7: ...ANSI pumps Inlet Port c Outlet Port b Counterclockwise Rotation CCW Inlet Port b Outlet Port c b a c b a c CCW Rotation CW Rotation 3 2 Taps b and c in the gland are buffer barrier fluid inlet and ou...

Page 8: ...is tics and shaft speed 3 5 The Flowserve supply tank is designed to work with the P 200 seal to form a self contained sealing system The circulating feature in the P 200 provides a positive buffer ba...

Page 9: ...e Supply tank assembly normally open Level switch low Pressure switch low Pressure indicator Cooling coils Drain normally closed Piping Plan 11 53A Vent 1 2 m 4 feet maximum 0 45 0 6 m 1 5 2 feet mini...

Page 10: ...tings consult Flowserve 4 2 Do not exceed the pressure velocity P V limits 4 3 Do not exceed the temperature limits of the P 200 The materials of construction are listed on the assembly drawing For th...

Page 11: ...mber A spare backup seal should be stocked to reduce repair time When seals are returned to Flowserve for repair decontaminate the seal assembly and include an order marked Repair or Replace A signed...

Page 12: ...rain its employees and contractors in the safe use of Flowserve products in connection with the specific application While the information and specifications contained in this literature are believed...

Reviews: