![Flowserve ColdFlow 341000 User Instructions Download Page 3](http://html1.mh-extra.com/html/flowserve/coldflow-341000/coldflow-341000_user-instructions_2308385003.webp)
3
Kämmer Series 341000 FCD KMENIM4104-01 03/18
2
INITIAL INSTALLATION
2.1 Unpacking
2.1.1 Valve and Actuator are delivered separately. This
allows for more compact transport boxes and easier
installation. After unpacking the valve and actuator,
clearly mark the parts for proper assembly. The trim is
installed inside the valve body to avoid damage during
transport. To remove the trim assembly from the valve
please refer to section 3.1
2.1.2 Marking (figure 1)
Valve components have been marked with the serial
number in order to allow a proper disassembly and
assembly. The valve body is marked on top of the
cover plate (1.1), trim kit at the upper part of the
extension(1.2) and the bonnet on the side (1.3). All
relevant technical data is shown on a stainless steel
nameplate attached to the actuator. See also section 5
Identification.
2.2
Preparation for vacuum box installation
(figure 2)
2.2.1 After trim has been removed from the valve body (see
chapter 3.1) mount the installation flange (2:1) on the
bonnet flange thread of the valve.
CAUTION:
Please ensure that the mounting flange has
been tightened with the correct torque (see table 7.3).
2.2.2 Attach hoisting equipment of adequate lifting capacity
to the hoisting lug (3:1) and lower the valve body into
the vacuum box. See also table 7.2 for approximate
maximum weights of this subassembly.
CAUTION:
take care when lowering the valve
subassembly into the vacuum box.
Mounting (figure 3)
Insert the mounting Tool (3.1) between the valve
cover plate (3.2) and the mounting flange (3.3) before
reaching the final position inside the box.
Figure 1: Marking
Figure 2: Mounting Preparation
Figure 3: Mounting
1.2
1.3
2.1
3.1
3.2
3.3
1.1