7.5 Switch option specifications (continued)

NS      Solid State Proximity  Fuchs 

NJ4-12GM40-E2 

NPN Sourcing / 200 mA max. 

 

   

 

 

Current / 10-60 VDC

NT     Solid State Proximity  Fuchs 

NJ4-12GK40-E2 

NPN Sourcing / 200 mA max. 

 

   

 

 

Current / 10-60 VDC

NV      Solid State Proximity  Fuchs 

NJ2-11-N-G 

NAMUR Sensor Output / 5-25 VDC Supply

NW      Solid State Proximity  Fuchs 

SJ3,5-SN 

NAMUR Sensor Output / 5-25 VDC Supply

NX    

 

NBB2-V3-E3

NY     Solid State Proximity  Fuchs 

NJ4-12GK-SN 

NAMUR Sensor Output / 5-25 VDC Supply

P4      SPST Proximity 

Aleph 

PS-6132 

0.35A at 140 VAC / .25A at 200VDC

 

   

 

 

(50 W Max.)

P5      SPDT Proximity 

Hamlin 

59135-030 

0.25A at 120 VAC / 0.25A at 28 VDC (3 W Max.)

PE      SPDT Sabre Pxy 

Flowserve 

XA0199 

1A at 120 VAC / 1A at 24 VDC 

PP     SPDT Phazer Pxy 

Flowserve 

XA0155 

3A at 120 VAC / 2A at 24 VDC

PT     SPST BRS Pxy 

Flowserve 

XA0157 

3A at 120 VAC / 0.5 at 24 VDC

R1    

Fuchs

 NBB3-V3-Z4-3G-3D

R2    

Fuchs

 NBB2-V3-E3-3G-3D

R3    

Fuchs

 NBN4-V3-E2-3G-3D

Code     Switch Option           Manufacturer       Part Number             Load Capacity

FCD ACENIM0135-02 - 09/16

Summary of Contents for Accord WS/WM Ultraswitch

Page 1: ...USER INSTRUCTIONS Installation Operation Maintenance FCD ACENIM0135 02 09 16 Accord WS WM Ultraswitch Switchbox...

Page 2: ...enclature 5 5 5 WS WM UltraSwitch switch options 6 6 INSTALLATION 8 6 1 Wiring instructions 9 6 2 Cover and housing options 10 7 SWITCHES Certified 11 7 1 Installation in hazardous locations 11 7 2 Ad...

Page 3: ...2 locations Inspect periodically for degradation Replace parts if degradation is found Cleaning this housing by rubbing should be done in a non hazardous area Potential electrostatic charging hazard c...

Page 4: ...berglass filled or Transparent Polycarbonate Shaft Stainless Steel SS EN 2346 AISI 303 Cams Splines Nylon Terminal Block Nylon Internal Brackets Nylon Aluminum or Stainless Steel All Internal Fastener...

Page 5: ...Conduit entries D Number of conduit entries 2 2 conduit entries 4 4 conduit entries 2 according to C entries opposite side with different type of th reading E Body material A Aluminum R Engineered res...

Page 6: ...VAC 0 25A 200VDC 50 W Max P5 A B C SPDT Proximity Hamlin 0 25A 120 VAC 0 25A 28 VDC 3 W Max PE A B C SPDT Sabre Proximity Flowserve 1A 120 VAC 1A 24 VDC PP C SPDT Phazer Proximity Flowserve 3A 120 VAC...

Page 7: ...S WM Nomenclature on page 5 2 Some models have more than two open terminal locations open as standard Consult factory for details Code Certificate A ATEX II 1GD Ex ia IIC T4 T5 T6 ATEX II 1GD Ex ia II...

Page 8: ...direct coupling to actuators without couplings reducing dead band Bolt bracket to actuator and WS WM Ultraswitch to bracket leaving bolts finger tight For NAMUR applications the WS WM Ultraswitch swi...

Page 9: ...clockwise position the bottom switch should only be used to indicate the counter clockwise position Any deviation from these settings may result in erratic indication Solenoids may also be wired thro...

Page 10: ...minum housing Resin housing Aluminum or Resin cover Arrow Indicator Polycarbonate transparent cover Arrow Indicator Polycarbonate transparent cover Dome Indicator Aluminum or Resin cover flat 6 2 Cove...

Page 11: ...ust cam s as sociated with CW as follows 1 Push or pull cam against spring to disengage it from splines 2 Rotate cam CW breaking contact with switch or moving magnet away from switch 3 Continue rotati...

Page 12: ...erl Fuchs NJ4 12GM40 E N2 Pepperl Fuchs NJ2 12GK N N3 Pepperl Fuchs SJ3 5 S1N N4 Pepperl Fuchs NJ2 12GK SN N5 Pepperl Fuchs NJ4 12GK40 E N6 Pepperl Fuchs NJ4 12GK40 E1 N7 Pepperl Fuchs NBB2 V3 E0 N8 S...

Page 13: ...2 V3 E3 NY Solid State Proximity Pepperl Fuchs NJ4 12GK SN NAMUR Sensor Output 5 25 VDC Supply P4 SPST Proximity Aleph PS 6132 0 35A at 140 VAC 25A at 200VDC 50 W Max P5 SPDT Proximity Hamlin 59135 03...

Page 14: ...14 8 Dimensions WS body enclosure WM body enclosure FCD ACENIM0135 02 09 16...

Page 15: ...67 Gasket for cover all cover types 1 2 3 4 5 The Rotary Limit Switch Box is marked with the following warning marking WARNING POTENTIAL ELECTROSTATIC CHARGING HAZARD SEE INSTRUCTIONS Enclosure materi...

Page 16: ...t Locator System found at www flowserve com Flowserve Corporation has established industry leadership in the design and manufacture of its products When properly selected this Flowserve product is des...

Reviews: