3) 

Support the center resonator with a stand and loosen the four nuts at the two band clamp 

connections at the resonator inlet. Using a screwdriver, pry up the clips on the clamp body to release 
the clip from the tab on the inlet pipes. Slide the clamp assemblies slightly back to clear the tabs. You 
can now lower the rear of the resonator and slide the assembly to the rear of the vehicle to remove. 
Lower the resonator from the vehicle and set aside.

  

 
 

Installation: 
 

 

1) 

Slide a supplied 

TB810S

 adapter pipe onto the 

end of each outlet of the 86348 X-pipe assembly. 
Place a supplied clamp onto the connections and 
tighten enough to hold.  
 
 
 
 
 
 
 
 

 

 

 
 
2) 

Remove the factory band clamps from the factory exhaust system and place them onto the 

downpipes behind the catalytic converters. Place the 

86348S

 X-Pipe assembly into place behind the 

factory downpipes, support the rear of the assembly with a stand. Slide the clamps back to the bump 
stops on the X-Pipe and tighten both band clamps enough to hold, but still allow for adjustment. Be 
sure that the X-Pipe assembly is fully forward, and that the embossed Flowmaster in the center case 
is facing the ground before tightening. 
 
3) 

Place a supplied clamp over the inlet pipe of the passenger side stock muffler. Slide the 

muffler toward the rear of the vehicle and place the inlet into the adapter at the back of the X-Pipe 
assembly. Slide the clamp onto the slip connection and tighten enough to hold in place. Repeat this  
step on the drivers’ side of the vehicle. 
 
 